5
Specifications
Input
Volts
85 - 265VAC, 1 Phase, 45 - 65 Hz
Current (max) *
4 Amps w. Inrush Protection
Input Fuse
AGC 5 Amp
Power Factor
> 0.99 at Full Load
Efficiency
> 90% at Full Load
*
Maximum Input Current Specified at 85 VAC
Output
Nominal Voltage
12 VDC
24 VDC
32 VDC
48 VDC
Voltage Range **
12.0 - 15.5 VDC
24.0 - 31.0 VDC
32.0 - 41.3 VDC
48.0 - 62.0 VDC
Output Current
20 Amps
10 Amps
7.5 Amps
5 Amps
Recommended Battery Amp-Hours
100
50
40
25
Standard Temperature Compensation
-15mV/C
-30mV/C
-40mV/C
-60mV/C
Number of Battery banks
1 or 2
Charging Stages
2 or 3 stage user selectable
End of Charge
Float or Rest user selectable
** Actual Output Voltage determined by User Settings or by Charger Firmware
Mechanical
Dimensions
9.5”/24.1cm Long x 8.0”/20.3cm Wide x 3.25”/8.3cm High
Clearance
2.0”/5.0cm all around
Weight
6.2 lb / 2.8 kg
Material and Finish
Marine Grade Black Anodized Aluminum with 18-8 Stainless Fasteners
Mounting
Wall or Shelf Mount
Connections
Integrated Color Coded Terminal Blocks
Environmental and Safety
Operating Temperature Range
-25 to +40 C (-40 to +55 C Optional)
Storage Temperature Range
-55 to +85 C
Humidity
0 - 95% Relative Humidity (non-condensing)
Vibration
Built to meet MIL810g
Emissions
Complies with FCC Class B, Part 15
Isolation
> 1500 VDC Input-Output, Input-Case, Output-Case
Audible Noise
None
Duty Cycle
Continuous
Warranty
Five Years Parts and Labor
Safety
Built to meet ABS, CE, UL458 and CSA 22.2.107.1
* Specifications subjects to change without notice.
Designed and manufactured by:
ANALYTIC SYSTEMS WARE (1993) LTD.
8128 River Way
Delta, BC V4G 1K5 Canada
p. 604.946.9981 f. 604.946.9983
tf. 800.668.3884 US/Canada
www.analyticsystems.com
Summary of Contents for IBC320