![Analytic Systems BCD90 Installation & Operation Manual Download Page 4](http://html1.mh-extra.com/html/analytic-systems/bcd90/bcd90_installation-and-operation-manual_2940515004.webp)
4
* Specifications subjects to change without notice.
Designed and manufactured by:
ANALYTIC SYSTEMS WARE (1993) LTD.
8128 River Way, Delta, BC V4G 1K5 Canada p. 604.946.9981 f. 604.946.9983 tf. 800.668.3884
www.analyticsystems.com
[email protected] Revised July 2014
Specifications
Input Volts
Nominal
24
36
48
72
Min / Max
20 / 32
30 / 48
40 / 64
60 / 96
Output V
olts
Nominal
Actual
Output Amps
Output Crowbar
12
13.6
10.0
8.1
7.0
5.7
16
24
27.2
5.7
5.0
4.1
32
36
40.8
4.1
3.3
45
48
54.4
2.9
60
Volts
Continuous
Volts
Electrical
Input Ripple & Noise
< 100 mV Peak to Peak
Output Ripple & Noise
< 50 mV Peak to Peak
Transient Response
< 150 mV for 50% Load Step Change
Regulation (Line & Load)
< +/- 0.5%
Overload Capability
120% rated current for 1 minute max at 10% duty cycle
Efficiency
> 93% @ Maximum Output
Environment Specification
Operating Temp. Range
-20°C to +55°C @ maximum output
Humidity
0 – 95% Relative Humidity
Audible Noise
NONE Ødb @ 3 ft
Typical Service Life
> 10 yrs. (87,600 hrs)
Isolation
Any Input or Output to Case 500 VDC, 1500 VDC for 48 and 72 input
Mechanical Specification
Length
4.12 in / 10.5 cm
Width
4.30 in / 10.9 cm
Height
1.56 in / 3.96 cm
Material
Marine Grade Aluminum
Finish
Red Anodized / Powder Epoxy Coat
Fastenings
All 18-8 Stainless Steel
Weight
0.62 lb / 0.28 kg
Warranty