5
Introduction
All new Current Mode switching design offers increased power and reliability in a compact
package. Extra input and output filtering reduce EMI to extremely low levels. Reliability
features include an input fuse, thermal shutdown, current limiting, reverse battery hookup
protection and output short circuit shutdown with automatic recovery. The output voltage is
easily adjusted 1.0 volts above or below the standard output voltage. The model BCD615R
Battery Charger supplies either
12, 24, 32 or 48 VDC from a 110, 250 or 300 VDC
power
source. High quality digital meters can be added (factory option) to allow monitoring of charg-
ing current and charging voltage.
Specifications
Input Voltages
Nominal (ip)
24
48
72
Actual
20-35
40-60
65-90
Input Amps (max)
37.9
19.4
12.1
Input Fuse (ATC)
15 x 3
25 x 1
25 x 1
Output Voltages
Nominal (op)
12
24
48
Output Volts (DC)
13.6 ± 0.05
27.2 ± 0.05
54.4 ± 0.05
Absorption Voltage (Vdc)
14.4
28.8
57.6
Charging Amps
40
20
10
Absorption to Float
6.0 Amps
3.0 Amps
1.5 Amps
Battery Size (Amp Hour)*
160 – 240
80 – 132
40 - 60
Output Fuse (ATC)
40 x 2
30 x 2
15 x 2
Battery Banks
1 or 2 (3 available) 1 or 2 (3 available) 1 or 2 (3 available)
Output Adjustment (Vdc)
± 1.0 Volts
Output Crowbar
16.0 ± 0.5 V
32.0 ± 1.0 V
63.9 ± 2.0 V
Temperature Compensation Coefficient
-30mV / o C
-60mV / o C
-120mV / o C
Effeciency
>75% @ maximum output
Environmental Specifications
Operating Temp. Range
-25° to +40°C @ maximum output
Derate Linearly 2.5% per °C from 40°C
(Optional -40°C extra wide temp. operation avail.)
Humidity
0 - 95% Relative Humidity
(non-condensing) with optional conformal coating
Audible Noise
NONE Ødb @ 3ft (34.5 dB when fan operating)
Typical Service Life
> 10 yrs. (87,600 hrs)
Isolation
Input-Case & Input-Output 1500 Vdc (500V @ 24V I/P)
Output-Case 500 Vdc @ 48V O/P)