background image

6

Installation

MOUNTING

Mount the unit and allow at least 4 inches of clearance around the heat sink fins for adequate 

cooling.

POWER CONNECTION

The unit is supplied with power leads about 8 feet long. This should normally be adequate to 

connect to a source of power. If you must extend the power leads, be sure to use at least a 

good quality (typeTEW) AWG 8 gauge wire. The wire colours are: 

Operation

Once you have decided on the charging profile you must set the switch to the correct 

position. Set the switch to the correct position as shown on the label. 

To turn the unit on, simply move the power switch to the ON position. The alarm buzzer will 

sound and the Low Output LED will come on briefly, and then the green OUTPUT ON LED will 

illuminate. 

When the unit is first turned on, it will charge the batteries at a constant current and 

the charging light will be on. After a period of time, which may be minutes to hours, the 

batteries will reach the float voltage at which time the charging light will go off, and the 

charging current will reduce as necessary to maintain the batteries at that voltage. You may 

check this voltage at the output terminals of the unit with a good digital voltmeter. 

110 VAC

Black/Brown - AC Hot

White/Blue - AC Neutral

Green - Ground

All connections should be made inside an appropriate junction box. The maximum current 

draw from the 110 VAC supply is 14 amps, so a 20 amp circuit breaker should be used in the 

circuit panel.

The unit is supplied with two AWG 8 gauge wires. The red wire is the output positive. The 

black wire is the output negative.

Output Connection

Summary of Contents for BCA1505MW-24

Page 1: ...24 Battery Charger 8128 River Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers Inv...

Page 2: ...Copyright 2005 2015 Analytic Systems Ware 1993 Ltd Revised May 18 2016...

Page 3: ...AC POWER CORD CONNECTION INSTRUCTIONS The plug must be plugged into an outlet that is properly installed and grounded in accordance with al local codes and ordinances DANGER Never alter AC cord or plu...

Page 4: ...e Power Supply the charger simultaneously powers the DC load as well as the battery As long as the AC power to the charger is available and the charger is working normally the charger will supply the...

Page 5: ...minum Finish Black anodized Fastenings 18 8 Stainless Weight 21 lb 9 5 kg Safety ABS 11 HS794404E PDA Designed and manufactured by ANALYTIC SYSTEMS WARE 1993 LTD 8128 River Way Delta BC V4G 1K5 Canada...

Page 6: ...ly and then the green OUTPUT ON LED will illuminate When the unit is first turned on it will charge the batteries at a constant current and the charging light will be on After a period of time which m...

Page 7: ...is the fastest charger It charges the battery at a constant current until the battery voltage reaches a slightly elevated level The battery is maintained at this voltage while the charging current dim...

Page 8: ...ENSOR The battery temperature sensor can be connected to the charger to allow temperature compensation of the battery charging voltage 1 is supplied with the unit The charger will work without the bat...

Page 9: ...not high enough for unit to operate LOW INPUT Indicates that the input voltage is below normal because The input voltage is not in the correct range for proper operation of the unit OVERTEMP Indicates...

Page 10: ...10 Page intentionally left blank...

Page 11: ...ng will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed o...

Page 12: ...Way Delta B C V4G 1K5 Canada T 604 946 9981 F 604 946 9983 TF 800 668 3884 US CANADA www analyticsystems com An ISO9001 and AS9100 Registered Company Battery Chargers Inverters Power Supplies Voltage...