Analog Metric EL34 SE V User Manual Download Page 5

[EL34 SE V Amplifier Full Kit] 

Analog Metric

 

 

 

www.analogmetric.com

 

 

5

 

PRECAUTIONS 

 

Do not use any body parts to touch the metal parts of the kit after power up or power 
off, since the high voltage capacitors may not fully discharge. It may cause serious 
electric shock. 

 

Use a power transformer with fuse (1-3A) socket to limit the supply current in case of 
short circuit or incorrect assembly. 

 

Double check the assembled components with the part list. 

 

Do not attempt the measure the voltage by multimeter with hand after power up. The 
probes of the multimeter should be mounted by some stands to the points of the 
measurement before switching on the power supply. 

 

Turn off the power supply if you observe any smokes or hear strange sound coming 
out from the transformer or board. If there is short circuit, the transformer will be 
getting very hot shortly. 

 

PROCEDURES 

1.

 

Solder the resistors on the top of the board, and then the tube sockets according to the 
part list. The resistance of the Dale resistors should be faced upward for easy of future 
debugging. 

2.

 

Solder all remain components on the bottom of the board. Notice to the direction of 
the electrolytic capacitors C1, C4, C6, C7, and C8. There is no direction of the thin 
film  capacitors.  Double  check  the  direction  of  the  electrolytic  capacitors,  as  it  may 
cause hazardous. 

3.

 

Apply two 6.3V DC/AC (1.5A) to H2, and one or two 280V DC (100mA) to P1. The 
tube  filament  will  be  growing  up  gradually.  Turn  off  the  power  supply  if  there  is  a 
suddenly dropping in the supply voltage at P1, H1, and H2, and double check all the 
electrolytic capacitors. 

4.

 

Connect the output transformer to B+, ROUT and LOUT. 

 

Reviews: