EVALUATION BOARD SOFTWARE
MAIN CONTROLS
The
Main Controls
tab (see Figure 5) selects the RF and user
configurable register settings. Consult the register descriptions
in the
data sheet for details. Default settings are rec-
ommended for most registers.
In
RF Settings
, ensure that
VCOout (MHz)
equals the
VCO frequency. Set
Output divider
to give the required
RFoutA± (MHz
).
Ensure that
Reference freq
equals the applied reference signal. The
PFD frequency is calculated from the reference frequency, the
R counter, the reference doubler, and the reference divide by 2.
Ensure that the value in
PFD (MHz)
matches the value specified in
the loop filter design.
In
Register 4
, program
CP current
to match the value used for
the loop filter design.
Figure 5. Software Front Panel Display—Main Controls