5
Rev. 0
AUXILIARY SUPPLY INPUT
1. Place and connect test equipment (voltmeter, amme-
ter, oscilloscope and electronic load) as shown in
2. Turn down the electronic load to a minimum value
and turn off the electronic load.
3. Connect the output of the auxiliary supply to the
DC2911A as shown in Figure 6. Turn on the auxiliary
QUICK START PROCEDURE
supply and set its current limit to 2A. Then increase
its output voltage to 48V.
4. Once the LED (D3) on the DC2911A is lit, check the
output voltage using a voltmeter. Output voltage
should be within 37V to 57V.
5. Verify
T2P
response with an oscilloscope as shown
in Figure 6. The
T2P
response during auxiliary power
operation is provided in Table 3.
Figure 6. Setup Diagram for Auxiliary Supply Input
DC/DC
CONVERTER
PSE TYPE
(TO μP)
OPTO
ENABLE
+
–
V
IN
V
IN
AUXILIARY
DC POWER
SUPPLY
+
–
DC2911A F06
Table 3.
T2P
Response During Auxiliary Power Operation
PD CLASS
T2P
RESPONSE
0 – 4
Logic Low
5 – 8
75% Logic Low*
*
T2P
Frequency is 840Hz typical