4
UG-1339 Rev 0
DEMO MANUAL DC2685A
QUICK START PROCEDURE
Table 1. DC2684A 4PV# Jumper Settings
JUMPER
SETTING
OPERATION
4PV# (JP2)
LO
Port powered only when both
pairsets present a valid signature
HI
Any pairset presenting a valid
signature is powered
Table 3. DC2685A Power Supply Voltage Range per PSE Type
IEEE TYPE
Supply Voltage Range
Type 3
51V to 57V
Type 4
53V to 57V
Table 4. DC2685A Address Settings
SW3
ADDRESS
AD3
AD2
LO
LO
20h
LO
HI
24h
HI
LO
28h
HI
HI
2Ch
Table 2. DC2684A Auto Mode Maximum Delivered Power Capabilities
Jumper Settings
PM1
(JP4)
PM0
(JP3)
Max Port Power
(Single-Signature)
Max Pairset Power
(Dual-Signature)
LO
LO
40W
13W
LO
HI
51W
25.5W
HI
LO
62W
25.5W
HI
HI
71.3W
35.6W
Figure 3. DC2685A Kit Connections