OPTIMIZING AND RUNNING THE 

ADPD1080

/ 

ADPD1081

 

After the configuration file is loaded, the settings can be further 
optimized using the 

ADPD Config 

window shown in Figure 11. 

Typically, the device is set up under some set of conditions, for 
example, measuring the response from a fixed reflector or 
measuring a PPG signal from the wrist (see Figure 12). Settings 
can be optimized for any set of conditions by manipulating LED 

drive currents, TIA gain, and AFE timing or by using different 
operating modes that may be more optimal for a specific set of 
conditions, for example, using float mode for very low current 
transfer ratio (CTR). For information on optimization of the 

ADPD1080

/

ADPD1081

, refer to th

ADPD1080

/

ADPD1081

 data 

sheet. For functional descriptions of the Applications Wavetool, 
refer to the Applications Wavetool user guide that is provided in 
the software package download. 

16616-

012

 

Figure 12. Example of a PPG Signal Measured from the Wrist 

 
 
 

Summary of Contents for ADPD1080/ADPD1081

Page 1: ...provides users with a simple means of evaluating the ADPD1080 ADPD1081 photometric front end with an optimized discrete optical design for vital signs monitoring applications The evaluation system inc...

Page 2: ...ing the Applications Wavetool 3 Connecting the EVAL ADPDUCZ Microcontroller Board and the EVAL ADPD1081Z PPG Evaluation Board 3 Checking the USB Serial Connection in Windows 3 Running the Applications...

Page 3: ...microcontroller board is on SWITCH TO ON 16616 004 Figure 3 Connect the EVAL ADPDUCZ to the EVAL ADPD1081Z PPG CHECKING THE USB SERIAL CONNECTION IN WINDOWS Ensure that the COM port driver is installe...

Page 4: ...Demo by going to Start All Programs STMicroelectronics DfuSe DfuSe Demo Figure 8 shows the DfuSe demo settings at startup 7 In the Upgrade or Verify Action section click the Choose button and select...

Page 5: ...s a window that allows the user to run the ADPD1080 ADPD1081 device and collect data see Figure 12 16616 010 Figure 10 Select ADPD Device LOAD CONFIGURATION In the upper right corner of the data view...

Page 6: ...2 Settings can be optimized for any set of conditions by manipulating LED drive currents TIA gain and AFE timing or by using different operating modes that may be more optimal for a specific set of co...

Page 7: ...GND_LOCAL DUT_LED_SEL GND_LOCAL DUT_LED_DRIVE2 DUT_TCLI DUT_SCLK DUT_LED_DRIVE2 GND_LOCAL GND_LOCAL GND_LOCAL DUT_MISO DUT_INT_ACCL DUT_TCLI DUT_LED_DRIVE1 GND_LOCAL DUT_VCC DUT_CS_N_ADXL DUT_MOSI DU...

Page 8: ...UG 1255 EVAL ADPD1081Z PPG User Guide Rev 0 Page 8 of 9 16616 014 Figure 14 EVAL ADPD1081Z PPG Primary Layer 16616 015 Figure 15 EVAL ADPD1081Z PPG Secondary Layer...

Page 9: ...ny other party for any reason Upon discontinuation of use of the Evaluation Board or termination of this Agreement Customer agrees to promptly return the Evaluation Board to ADI ADDITIONAL RESTRICTION...

Reviews: