ADP5350CP-EVALZ User Guide
UG-1104
Rev. 0 | Page 9 of 15
USING THE EVALUATION BOARD
POWERING UP THE EVALUATION BOARD
The
ADP5350CP-EVALZ
evaluation board is supplied fully
assembled and tested. Before applying power to the evaluation
board, follow the procedures in this section.
Input Jumpers
Because VIN123 and VIN4 must be connected to VSYS, the
input jumpers, S1 and S2, are shunted by default.
Quick Start
A typical test setup follows:
1.
Connect the
USB-SDP-CABLEZ
cable from the computer
USB port to the
ADP5350CP-EVALZ
evaluation board.
2.
Use a dc power supply to connect VBUS and GND on the
ADP5350CP-EVALZ
. Set the VBUS supply to 5. 0 V, and
turn the power on. If evaluation of the charge function is
not required, skip this step.
3.
Use a charged battery or a battery simulator to connect
ISOB and GND.
4.
Start the GUI software.
Figure 15.
ADP5350CP-EVALZ
LFCSP Board Connection Diagram
LDO3
OUTPUT
LDO2
OUTPUT
LDO1
OUTPUT
BATTERY
OR
BATTERY
SIMULATOR
DC 5V
SUPPLY
SYSTEM
LOAD
TO USB I
2
C
DONGLE
15553-
0
15