BUTTON BAR OF MAIN WINDOW 

The buttons described in this section provide easy access to 
common features. 

Load and Save 

Clicking 

Load

 and 

Save 

allows you to load and save an AD9551 

setup file. A setup file (.STP) is a text file that contains the AD9551 
register setup file, plus any evaluation board settings. 

Update 

Clicking 

Update

 toggles the I/O update bit (Register 0x05, Bit 0) of 

the AD9551. 

Reset 

Clicking 

Reset

 resets the evaluation board and restores the 

AD9551 to its default power-up state. In addition, clicking 

Reset

 enables the VCO calibration function by writing the 

enable VCO calibration bit. 

USING SOFTWARE TO CONTROL THE 
FUNCTIONAL BLOCKS OF AD9551 

The AD9551 evaluation software contains subsections that 
correspond to the major functional blocks of the AD9551. 
These subsections, most of which have their own window, are 
described in this section.  

You can access each window by clicking 

Click for Details

 in the 

appropriate subsection box of the main window. 

Most subsection boxes in the main window have a checkbox 
labeled 

SPI

. If this box is selected, the software allows serial 

port writes when conditions are changed in the corresponding 
subsection window. 

When a subsection window closes after clicking 

OK

, you may 

notice that the 

LOAD

 button on the main window starts 

blinking. This indicates that there are settings that have not 
been loaded to the AD9551 evaluation board. Click 

LOAD

 to 

load these settings to the evaluation board.  

Reference Input Boxes 

The reference input boxes, which are labeled 

REF A (MHz)

 and 

REF B (MHz)

 in the main window, allow you to select an input 

frequency for REF A and REF B (see Figure 9 for an example for 
REF A). These boxes can be used to change the logic levels of 
the input frequency select pins.  

0

81

29

-00

9

 

Figure 9. REF A List Box (in Main Window) 

Reference Dividers 

Clicking 

Click for Details

 in the 

REF A Divider

 and 

REF B 

Divider

 boxes of the main window accesses the 

RefA Input 

Divider

 window and the 

RefB Input Divider

 window (see 

Figure 10 for an example of the 

RefA Input Divider

 window).  

These windows are used to set the desired reference divider for 
the integer or Σ-Δ modulator mode. The counters can be set 
individually.  

08129-

011

 

Figure 10. RefA Input Divider Window 

Summary of Contents for AD9551

Page 1: ...AD9551 evaluation board and includes detailed schematics and PCB layout artwork The AD9551 Revision D evaluation board is a compact easy to use platform for evaluating all features of the AD9551 multi...

Page 2: ...d Software 4 Installing the Software 4 Using the Software 4 Guide to Programming the AD9551 5 Using an SPI Port 5 Using Dip Switches Manual Control 5 Using Software to Override Dip Switches Software C...

Page 3: ...Next The Found New Hardware Wizard may appear twice and a system restart may be required Refer to the Evaluation Board Software section for details on running the AD9551 evaluation board software SET...

Page 4: ...the evaluation board to the PC 2 Double click AD9551 Eval Software to run the AD9551 evaluation software A hardware installation window appears Depending on whether the evaluation board was found by...

Page 5: ...s to low Note that S2 controls REF B If REF B is not used there is no need to change the S2 settings 4 Connect a signal generator to REF A SMA Connector J1 By default the reference inputs on this eval...

Page 6: ...re outlined in this section From the main window the window for each functional block can be accessed by clicking the appropriate box in the main window When a subsection window closes after clicking...

Page 7: ...u allows you to select which evaluation board the software controls see Figure 5 Click Refresh List to detect a recently connected evaluation board 08129 005 Figure 5 Select USB Device Window Selectin...

Page 8: ...ion boxes in the main window have a checkbox labeled SPI If this box is selected the software allows serial port writes when conditions are changed in the corresponding subsection window When a subsec...

Page 9: ...Input PLL DCXO Window Clicking Click for Details in the PLL DCXO box in the main window accesses the Input PLL DCXO window see Figure 12 08129 014 Figure 12 Input PLL DCXO Window PFD and Charge Pump W...

Page 10: ...e OutSel Pin drop down box see Figure 18 in the main window controls the logic level on the OUTSEL pin of the AD9551 However this value can be overwritten by using the SPI control register 08129 019 F...

Page 11: ...ioned for PC control 2 Verify that all five jumpers are in place on Connector P2 3 Set the positions of the S1 S2 and S3 dip switches to high 4 Click Calculate Device Settings in the main window of th...

Page 12: ...ings that have not been loaded to the AD9551 evaluation board Click LOAD to load these settings to the evaluation board 4 Select 19 44MHz Mode in the Input PLL Mode box and then click OK ESD CAUTION 5...

Reviews: