background image

Evaluation Board User Guide 

UG-002

 

Rev. 0 | Page 7 of 12 

MENU BAR OF MAIN WINDOW 

File Menu 

The 

File

 menu allows you to load a previously saved AD9551 

setup file or to save a new AD9551 setup file. A setup file (.STP) 
is a text file that contains the AD9551 register setup file, plus 
any evaluation board settings.  

To load a previously saved setup file, select 

Load Setup

 from 

the 

File

 menu. Note that you must still perform a VCO 

calibration. Alternatively, to save a new setup file, select 

Save 

Setup

 from the 

File

 menu.  

To exit the evaluation software, select 

Exit

 from the 

File

 menu. 

However, note that no checking is done to ensure that the 
existing setup is saved. 

I/O Menu 

The AD9551 evaluation system allows one PC to control 
multiple evaluation boards. The 

Select USB Device

 window, 

accessed by choosing 

Select Evaluation Board

 from the 

I/O 

menu, allows you to select which evaluation board the software 
controls (see Figure 5). Click 

Refresh List

 to detect a recently 

connected evaluation board. 

0

81

29

-00

5

 

Figure 5. Select USB Device Window 

Selecting 

Configure Serial Port

 from the 

I/O 

menu allows you 

to control how the USB controller interacts with the AD9551 serial 
port (see Figure 6) by configuring Register 0x00 (shown as 00H 
in Figure 8). 

08

12

9-

0

0

6

 

Figure 6. Serial Port Configuration Window 

View Menu 

The 

Debug

 window, accessed by selecting 

Debug Window

 from 

the 

View

 menu, allows you to write and read registers directly and 

to force the various configuration pins high or low (see Figure 7). 

 

08

12

9-

0

07

  

Figure 7. Debug Window 

The 

Register Map Debug

 window, accessed by selecting 

Register Debug Window

 from the 

View

 menu, allows you to 

write and read registers (see Figure 8).  

08

12

9-

00

8

 

Figure 8. Register Map Debug Window 

Help Menu 

Selecting 

Help

 from the 

Help

 menu opens the 

About AD9551

 

window, which contains information such as revision number, 
region information, and contact information. 

Summary of Contents for AD9551

Page 1: ...AD9551 evaluation board and includes detailed schematics and PCB layout artwork The AD9551 Revision D evaluation board is a compact easy to use platform for evaluating all features of the AD9551 multi...

Page 2: ...d Software 4 Installing the Software 4 Using the Software 4 Guide to Programming the AD9551 5 Using an SPI Port 5 Using Dip Switches Manual Control 5 Using Software to Override Dip Switches Software C...

Page 3: ...Next The Found New Hardware Wizard may appear twice and a system restart may be required Refer to the Evaluation Board Software section for details on running the AD9551 evaluation board software SET...

Page 4: ...the evaluation board to the PC 2 Double click AD9551 Eval Software to run the AD9551 evaluation software A hardware installation window appears Depending on whether the evaluation board was found by...

Page 5: ...s to low Note that S2 controls REF B If REF B is not used there is no need to change the S2 settings 4 Connect a signal generator to REF A SMA Connector J1 By default the reference inputs on this eval...

Page 6: ...re outlined in this section From the main window the window for each functional block can be accessed by clicking the appropriate box in the main window When a subsection window closes after clicking...

Page 7: ...u allows you to select which evaluation board the software controls see Figure 5 Click Refresh List to detect a recently connected evaluation board 08129 005 Figure 5 Select USB Device Window Selectin...

Page 8: ...ion boxes in the main window have a checkbox labeled SPI If this box is selected the software allows serial port writes when conditions are changed in the corresponding subsection window When a subsec...

Page 9: ...Input PLL DCXO Window Clicking Click for Details in the PLL DCXO box in the main window accesses the Input PLL DCXO window see Figure 12 08129 014 Figure 12 Input PLL DCXO Window PFD and Charge Pump W...

Page 10: ...e OutSel Pin drop down box see Figure 18 in the main window controls the logic level on the OUTSEL pin of the AD9551 However this value can be overwritten by using the SPI control register 08129 019 F...

Page 11: ...ioned for PC control 2 Verify that all five jumpers are in place on Connector P2 3 Set the positions of the S1 S2 and S3 dip switches to high 4 Click Calculate Device Settings in the main window of th...

Page 12: ...ings that have not been loaded to the AD9551 evaluation board Click LOAD to load these settings to the evaluation board 4 Select 19 44MHz Mode in the Input PLL Mode box and then click OK ESD CAUTION 5...

Reviews: