Anaheim Automation MBC25P11 User Manual Download Page 17

17

#L010128

June 2002

A - Acceleration/Deceleration

 

Format: 

A#_[value] - where # is the speed profile number 1 thru 4

 

Sample: 

A1_255 

Accel of profile 1 equals 255

 

Description:  This command sets the acceleration profile which can be an integer value  

be- 

 

 

 

tween 1 and 255. The lower the value the faster the pulse acceleration, so 

a 1 is    

 

 

the fastest profile and 255 is the slowest. These values are saved in the 

EEProm  

 

 

 

for standalone use.

 

Range:  

1 - 255

B - Base Speed

 

Format:  

B#_[value] - where # is the speed profile number 1 thru 4

 

Sample: 

B3_100 

Base Speed of profile 3 equals 100

 

Description:  This command sets the base (start) speed for motion. This value must be set be-  

 

 

fore motion begins and be less then the maximum speed. The pulses will ramp    

 

 

down to this speed after a soft limit is triggered and run at this speed until a hard   

 

 

limit is triggered. These values are saved in the EEProm for standalone use.

 

Range:  

77 - 3500

$ - Version Number Register

 

Format : 

$

 

Description:  This command requests the pulse generator to return the version number.

! -  Error Codes Register

 

Format : 

!

 

Description:  This  command  requests  the  pulse  generator  to  get  the  current  error  code  and 

print    

 

 

it to the screen.

C - Current Reduce Option

 

Format:  

C# - where # is 0 or 1

 

Description:  This command enables the driver to reduce current after pulses are done being    

 

 

sent. A 1 will enable current reduction, and a 0 will disable current reduction. This  

 

 

 

value is saved in the EEProm for standalone use.

+/- -  Direction

 

 

Format: 

+ or -

 

Description:  This command sets the direction output. A “+” sets the output to clockwise, and a   

 

 

“-” set the output to counterclockwise. This must be done when the pulses are    

 

 

not running. This value is saved in the EEProm for standalone use.

July 2018

Summary of Contents for MBC25P11

Page 1: ...Programmable Pulse Generator Driver User s Guide 4985 E Landon Drive Anaheim CA 92807 e mail info anaheimautomation com 714 992 6990 fax 714 992 0471 website www anaheimautomation com A N A H E I M A...

Page 2: ...ing Diagrams 8 Jumper Functions 9 Microstep Modes 9 Setting the Output Current 9 Reducing Output Current 9 Determining Output Current 10 Step Motor Configurations 10 Connecting the Step Motor 11 Circu...

Page 3: ...ty to store up to four different motion profiles The profiles include a base speed starting speed a maximum speeds running speed and acceleration deceleration The base speed has a range of 77 3500 Hz...

Page 4: ...rts at base speed and immediately ramps up to max speed B Run is still active Max speed is reached keeps running at max speed C Run is inactivated Motor stops imediately A Run is activated Starts at b...

Page 5: ...drawing for JP1 Direction When this input is not active the motor will be moving in the clockwise or direction When this input is active the motor will move in the counterclockwise or direction This i...

Page 6: ...y Output This is an open collector output that is capable of sinking 10mA It is current sinking when the pulse generator is operating sending pulses and open when the pulse generator is not sending pu...

Page 7: ...r Chopping Frequency 25kHz 30kHz Operating Tempature 0 70o C LEDs Green Power On Red Programming Error Yellow Clocks being received above 10Hz Com Port Settings 9600 N 8 1 Specifications Ordering Info...

Page 8: ...8 L010128 June 2002 Wiring Diagrams Two Motors One Motor Dimensions and Jumper Potentiometer Locations July 2018...

Page 9: ...s of microstepping are 200 400 800 and 1600 steps per revolution in a 200 step revolution step motor To set the divisor just select the divisor wanted 1 2 4 or 8 Refer to Motion Tab Sheet Jumper Funct...

Page 10: ...nt of the MBC25P11 This sets the peak output current of the sine cosine waves The specified motor current which is the unipolar value is multiplied by a factor of 1 0 1 4 or 2 0 depending on the motor...

Page 11: ...ages containg the connector descriptions and hookup diagrams Note The physical direction of the motor with respect to the direction input will depend on the connection of the motor windings To reverse...

Page 12: ...directly as the number of steps second The different max profiles are stored in EEprom for standalone use Range 77 to 15000 Acceleration Deceleration The acceleration and deceleration are by default...

Page 13: ...2 Open CD Drive Folder D or E 3 Double click the Setup Icon Getting Started 1 Double click on the SMPG10WIN icon to run the SMPG10WIN software 2 Apply power to the pulse generator unit 3 Set the appr...

Page 14: ...rator If commu nications is not established please refer to the troubleshooting section File Menu Setup Menu Exit Exit the SMPG10WIN software Connect Establish communications with the controller Commu...

Page 15: ...p sec Begin Motion Motor will ramp up to maximum speed and keep moving until a limit switch is triggered Soft Limit Motor will ramp down to base speed and continue running Hard Limit Stop any motor mo...

Page 16: ...e pulse generator will return a SMPG10 the current version number Note In direct talk mode each command is followed by a carriage return The unit communicates in half duplex mode therefore proper setu...

Page 17: ...after a soft limit is triggered and run at this speed until a hard limit is triggered These values are saved in the EEProm for standalone use Range 77 3500 Version Number Register Format Description...

Page 18: ...e base speed The mo tor will run at this speed until a soft limit or a hard limit is triggered These values are saved in the EEProm for standalone use Range 77 15000 R Microstepping Resolution Format...

Page 19: ...Run Stop input is released R If a 1 is sent back then the driver is in Full step mode If a 2 is sent back then the driver is in Half step mode If a 4 is sent back then the driver is in Quarter step If...

Page 20: ...nected to the appropriate power supply 2 Check for any blown fuses in line with the pulse generator 3 If problems still exist contact Anaheim Automation at 714 992 6990 Problem The pulse generator has...

Page 21: ...unning 8 Transmitt Error To many parameters sent back to the PC This is an internal error caused by the eeprom 16 Motor Error Motor speed profiles are set incorrectly Please make sure that the base sp...

Page 22: ...Warranty All Anaheim Automation products are warranted against defects in workmanship materials and construc tion when used under Normal Operating Conditions and when used in accordance with specifica...

Reviews: