AMX Lighting - Enclosure Worksheet Guide
6
AMX Lighting - Enclosure Worksheet Guide
PROlink PACK #
: This drop-down menu is used to specify the Radia Pack number from 1
- 10. These are the only valid choices. The default pack number for Slot 1 is #1. The pack
numbers sequentially start at 1. If the pack number is unknown, then the field can be left alone
using the default #1 or set to a blank using the drop down menu. When using multiple packs in
a PROlink system make sure the other Enclosure Worksheets have the AXlink Device number
identified. Multiple packs in a PROlink system will all share the same AXlink device number.
The DIP switches in the second section should reflect the number chosen in this cell. Pack #1
will have channels 1 - 6, pack #2 will have channels 7 -12, and so on up to pack #10 having
channels 55 - 60. PROlink
PACK #
uses a drop-down menu containing the
PACK
choices
listed below:
DIM#
: Use this drop-down menu to specify the dimmer number in a PROlink system. Valid
numbers ar from 1 - 60. Not all rows or slots will have a dimmer number. Each controller is
responsible for six channels of control. Enter the channel number (1-6) of each dimmer or
switch connected. A single enclosure space could have none, one, two, or three channels
connected. There can be several controllers in a single enclosure so the channel numbers may
be repeated on the same worksheet. A channel number is not the same as a zone number.
DIM#
uses a text field that allows three characters:
Description / Zone
: Use this cell to enter information to describe and name each zone.
Descriptions can include numbers, circuits, branches, fixtures, locations, or any combination
that suits the designer.
DESCRIPTION / ZONE
uses a text field that allows (30) characters:
• 1
• 6
• 2
• 7
• 3
• 8
• 4
• 9
• 5
• 10
• blank
Text field
Text field