Wiring a Power Connection

To use the 2-pin 3.5 mm captive wire connector with a 

13.5V

 

-compliant power 

supply, the incoming PWR and GND wires from the external source must be 

connected to their corresponding locations on the connector (FIG. 5). 
The connector uses locking screws to insure a connection to the device, so make 

sure to insert and tighten the screws before applying power.  

1.

Insert the PWR and GND wires on the terminal end of the 2-pin 3.5 mm 

captive wire cable. 
Match the wiring locations of the +/- on both the power supply and the 

terminal connector.

2.

Tighten the clamp to secure the two wires. 
Do not tighten the screws excessively; doing so may strip the threads and 

damage the connector.

3.

Verify the connection of the 2-pin 3.5 mm captive wire to the external 

13.5V

 

-compliant power supply and apply power.

Powering On/Off X Series G5 Panels

Modero X Series G5 touch panels may be powered on by touching and holding the 

Sleep

 button. To power off the panel, press and hold the Sleep button, and select 

Power Off

 on the on-screen menu (FIG. 6): 

Configuration and Programming

X Series G5 touch panels are equipped with a 

Settings

 menu that provides the 

ability to configure various features on the panels. To access the 

Settings

 menu, 

press and hold the Sleep button, and select 

Settings

.

Note: Information on the Settings menu, panel configuration, and programming is 

provided in the Modero X Series G5 Programming Guide, available at www.amx.com.

Setting the Panel’s Device Number and Device Name

1.

In the Settings menu, select 

NetLinx

. This opens a password keypad.

2.

Enter the panel password into the keypad (the default is 

1988

) and select 

OK

 to access the 

NetLinx

 page.

3.

Press 

Device Number

 to open the NetLinx editing window.

4.

Enter a unique Device Number assignment for the panel and press 

OK

.

5.

Enter a unique Device Name assignment for the panel and press 

OK

.

Configuring the Panel’s IP Address

The first step is to configure the panel’s IP address. Note that this only configures 

the panel to communicate with a network; it is still necessary to connect to the 

NetLinx Master (see 

Connecting to a NetLinx Master 

below).

Network Communication via DHCP

1.

In the 

Ethernet

 page, press 

DHCP/Static

 field to open the 

DHCP/Static 

window. Note that 

DHCP

 is the default setting.

2.

Select 

Host Name

, enter the new host name

3.

Press 

OK

 to save changes.

Network Communication via Static Address

1.

In the 

Ethernet

 page, press 

DHCP/Static

 to open the 

DHCP/Static

 window.

2.

Select 

Static

 to open the 

Static IP

 window.

3.

Press any field to open a keypad or keyboard (depending on the field), and 

enter the appropriate network address information.

4.

Press 

OK

 to save your changes and return to the 

Ethernet

 page.

Connecting to a NetLinx Master

To establish the type of connection to make between the panel and the NetLinx 

Master:
1.

In the 

NetLinx

 page, press 

Mode

 to choose the connection mode (

URL

Listen 

or

 Auto

): 

2.

If password security is enabled on the target Master, enter the Username 

and Password:
a.   Select 

Username

 to open the 

NetLinx

 window.

b.   Enter the 

Username

 and 

Password 

required by the Master.

c.   Press 

OK

 to save changes and return to the 

NetLinx

 page.

Related Software and Additional Documentation (at www.amx.com)

• Programming the Modero X Series G5 touch panels requires the use of the 

latest versions of NetLinx Studio and TPDesign5, both available to download 

at www.amx.com. Refer to the NetLinx Studio and TPDesign5 online help for 

information.

• For information on designing touch panel pages intended to optimize the 

Modero X Series G5 experience, refer to the 

G5 Considerations Guide

.

• For additional information on the MXT-2001-PAN panel, refer to the 

X-Series 

G5 Touch Panels MXD/T-1901-PAN & MXD/T-2001-PAN Instruction Manual.

• For detailed information on the Settings menu as well programming 

information and instructions on upgrading firmware, refer to the 

Modero X 

Series G5 Programming Guide

.

• Detailed specifications drawings for the MXD/T-2001-PAN are available to 

download from www.amx.com.

FIG. 5  

NETLINX POWER CONNECTOR WIRING DIAGRAM

FIG. 6  

SLEEP BUTTON - PRESS AND HOLD TO ACCESS POWER OFF/SETTINGS OPTIONS

PWR +

GND -

To the Touch Panel

Power Supply

CONNECTION MODES

Mode

Description

Procedures

URL

The device connects to the 

target Master’s IP address via 

a TCP connection.

1) Select 

URL

 in the 

Mode

 menu.

2) Enter the 

Master IP/URL

Master Port Number

and 

Username

/

Password

 (if required by the 

Master).

3) Press 

OK

 to save changes.

Listen

This mode allows the panel to 

“listen” for the Master’s 

communication signals. 

Note that in this mode, the 

System Number

 and 

Master IP/

URL

 fields are read-only.

1) Select 

Listen

 in the 

Mode

 menu.

2) Confirm the panel’s IP address is on the 

Master’s URL list (via NetLinx Studio).

3) Press 

OK

 to save changes.

Note

: The Host Name (set on the Ethernet page), 

can be used to locate the panel on the Master  

(particularly useful for DHCP connections where 

the IP address can change).

Auto

Use this mode when both the 

panel and the NetLinx Master 

are on the same Subnet.

1) Select 

Auto

 in the 

Mode

 menu.

2) Enter the System Number and Username and 

Password (if applicable). 

3) Press 

OK

 to save changes.