Using KPDesign
15
KPDesign Keypad Design Program
7.
Select the Add as Link option (if you do not want to copy the file to your project folder).
Source Code Entry
To include a module into your program, use the following module line:
DEFINE_MODULE 'DMS-IMSMod' Module_Name(Virtual_Dev, Real_Dev, strFileName,
strVarTextArray)
Where:
For example, a NetLinx module for a DMS keypad would look like:
DEFINE_MODULE
'
DMS-IMSMod
'
mdlDMS (dvDMS, dvDMS_R, strFILE_NAME,
StrVartextArray)
Where:
Sample NetLinx Code
To download a KPD file to a NetLinx Master, you must use the NetLinx DMS-IMS module, with
the following DEFINE_MODULE entry in the Master Source Code:
DEFINE_MODULE 'DMS-IMSMod' Module_Name(Virtual_Dev, Real_Dev,
strFileName, strVarTextArray)
Where:
Module_Name is a unique name. For example:
DEFINE_MODULE 'DMS-IMSMod' mdlDMS (…
or
DEFINE_MODULE 'DMS-IMSMod' mdlIMS (…
For example:
Module_Name
DMS-IMSMod.tko
Virtual_Dev
A virtual device you define.
Real_Dev
The device number of the DMS or IMS panel.
StrFileName
A string variable (CHAR array) containing the file name of the KPD file
to run.
StrVarTextArray
A two-dimensional array to store variable text in. The first dimension
should be the largest variable text number you want to use. The sec-
ond dimension should be the maximum size of the string you want dis-
played (maximum is 40 characters).
DMS-IMSMod
The name of the compiled TKO file.
MdlDMS
The module name.
DvDMS
The module ID device number (ex 32768).
DvDMS_R
The device number of the keypad.
StrFILE_NAME
Exact name of the KPD file.
StrVarText Array
Description of the parameters for the variable text buffer.