3. Insert the Retractable Cable Module into the HPX Base

1.

Orient the module relative to the HPX base assembly so that the Module’s 
faceplate is facing up, towards the mounting surface (FIG. 5).  

2.

Align the Mounting Notches on the module with the Mounting Rails on the 
HPX base.

Note

: Module faceplates are notched in a “tongue and groove" type fashion to 

ensure that all modules are oriented correctly in the HPX. Note the orientation of 
the notched faceplate on each module before sliding the module(s) into the HPX 
assembly.

3.

Slide the module into position.

4.

Install any remaining modules into the HPX base.

4. Re-Install the End-Cap

Caution

: Do not use a high-powered torque screw driver. Over-tightening these 

screws can damage the product.

1.

Align the Mounting Notches on the End Cap with the Mounting Rails on the 
HPX base.

2.

Slide the End Cap into the HPX base until it is fully inserted against the end 
of the base assembly.

3.

Secure the End Cap with the six (black) sheet metal screws (removed in 
Step 2 - 2; see FIG. 4).

4.

Replace the (silver) pivot screw and pivot pawl assembly (removed in Step 
2 - 1, see FIG. 4) in the center of the End Cap.

5. Mount the HPX into the Mounting Surface

Caution

: Do not use a high-powered torque screw driver. Over-tightening these 

screws can damage the product.

Note

: For detailed instructions on installing the HPX base assembly, refer to the 

HPX-600/900/1200 Installation Guide (available online at www.amx.com).

1.

Carefully insert the HPX base into the cutout in the mounting surface. 

2.

Tighten the four mounting screws (loosened in Step 1, see FIG. 3) located 
inside and at each end of the HPX base assembly, to rotate the retaining 
tabs into locking position under the mounting surface.

6. Terminate Fixed Cables

1.

Terminate fixed cables as necessary.

Note

: Use of an extension cable on either end of this cable should be 

avoided to ensure optimal performance.

2.

Replace any cable ties that were removed in Step 1. 

Retractable (Source) RGB + Audio Connector: 3.5mm Ports

Note that the retractable cable (which connects to the Source device) features 
two 3.5mm ports, one on either side of the RGB connector (FIG. 6): 

• The port with the 

Speaker

 icon is the active audio port - use this port to 

connect to the source device’s audio output (via the Stereo Audio Patch 
Cable).

• The port with the 

Plug

 icon is inactive. It is intended to be used as a 

storage port - use this port to store the Stereo Audio Patch Cable when not 
in use.

Mounting Dimensions

FIG. 7 provides dimensions for the retractable cable module, when installed in 
an HPX base assembly: 

       

Additional Documentation

Refer to the 

Products > Architectural Connectivity 

catalog page on 

www.amx.com

 (

Dealer Site

) for additional product documentation.

FIG. 5  

Retractable Cable Module - Mounting into an HPX Base Assembly

FIG. 6  

Retractable (Source) RGB + Audio Connector (Storage and Audio ports)

FIG. 7  

RCM Module (installed in an HPX base) - detailed dimensions

4.65”

(11.81 cm)

End Cap 

8.51”

(21.62 cm)

(of Base Assembly)