Installing Into an Equipment Rack

Use the optional AC-RK Accessory Rack Kit (

FG515

) to mount the Controller into a standard 19" 

equipment rack. 
1.

Discharge the static electricity from your body by touching a grounded object.

2.

Align the front of the NI-900 through any of the three rectangular openings on the AC-RK.

3.

Use the included mounting screws to secure the unit’s faceplate to the AC-RK. 

4.

Thread the cables through the opening in the equipment rack. Allow for enough slack in the 
cables to accommodate for movement during the installation process.

5.

Reconnect all cables to their appropriate source/terminal locations. Verify that the terminal 
end of the power cable is not connected to the a power supply before plugging in the 2-pin 
power connector.

6.

Align the ends of the AC-RK with the screw openings along the sides of the equipment rack.

7.

Secure the AC-RK to the rack by using the four #10-32 screws (80-0186) and four #10 
washers (80-0342) supplied in the kit.

8.

Apply power to the unit to complete the installation process.

Connections and Wiring

Preparing Captive Wires

You will need a wire stripper and flat-blade screwdriver to prepare and connect the captive wires.

Note

: Never pre-tin wires for compression-type connections.

1.

Strip 0.25 inch (6.35 mm) of insulation off all wires.

2.

Insert each wire into the appropriate opening on the connector (according to the wiring dia-
grams and connector types described in this section).

3.

Tighten the screws to secure the wire in the connector. Do not tighten the screws excessively 
doing so may strip the threads and damage the connector.

Wiring a Power Connection

To use the 2-pin 3.5 mm mini-Phoenix connector with a 12 VDC-compliant power supply, the 
incoming PWR and GND cables from the external source must be connected to their corresponding 
locations on connector (FIG. 2). 
1.

Insert the PWR and GND wires on the terminal end of the 2-pin 3.5 mm mini-Phoenix cable.

Match the wiring locations of the +/- on both the power supply and the terminal 
connector.

2.

Tighten the clamp to secure the two wires.

3.

Verify the connection of the 2-pin 3.5 mm mini-Phoenix to the external 12 VDC-compliant 
power supply.  

RS-232/422/485 Connector Information

FIG. 3 shows the pinout and wiring specification information for the rear RS-232/RS-422/RS-485 
(DB9) Device Port. This port support most standard RS-232 communication protocols for data 
transmission (the NI-900 uses only Port 1).  

WARNING:

 When wiring the 422/485 connections, do 

NOT

 use pre-made 9-wire cable or connect 

the wire in the cable to any connection that will not be used by the DB9 serial port. Only use wiring 
that connects the needed pins.

Ethernet 10/100 Base-T Connector

 

A standard CAT5 Ethernet cable provides 10/100 network connectivity between the Integrated 
Controller and the network (FIG. 4).  

  

    

  

Note

: On NetLinx Masters (such as those aboard the NI-900), from within the Telnet or Terminal 

applications; you can send the 

SET ETHERNET MODE 

command to assign the speed of your 

Ethernet connection. 

Sample NI-900 command:

    

SET ETHERNET MODE AUTO

The NI-900 only allows you to set the Ethernet mode to AUTO negotiate the Ethernet connection 
speed. Using any of the other connection modes (10 Half/Full or 100 Half/Full) results in an error 
message.

Program Port Baud Rate Settings

The Configuration DIP switch is located on the front panel. Use this DIP switch to set the baud rate 
for the Program Port, according to the settings shown in the following table. Make sure the baud rate 
you set matches the baud rate on your PC's NetLinx COM Settings before programming the unit. 

By default, the baud rate is set to 38,400 (bps)

Note: 

DIP switch 1 activates/deactivates the Program Run Disable Mode. DIP Switches 2,3, and 4 

must remain OFF at all times. 

Setting the Configuration (Program Port) DIP Switch

1.

Disconnect the power supply from the rear 2-pin PWR (green) connector.

2.

Set DIP switch positions according to the information listed in the previous Baud Rate 
Settings table.

3.

Reapply power to the unit.

Preparing the NI-900 for Serial Communication

1.

Launch NetLinx Studio 2.x (default location is 

Start

 > 

Programs

 > 

AMX Control Disc

 > 

NetLinx Studio 2

 > 

NetLinx Studio 2

).

2.

Select 

Settings

 > 

Master Communication Settings

, from the Main menu, to open the 

Master Communication Settings

 dialog box.

3.

Click the 

Communications Settings

 button to open the 

Communications Settings

 dialog.

4.

Click the 

NetLinx Master

 radio button (from the Platform Selection section) to indicate you 

are working with a NetLinx Master.

5.

Click the 

Serial 

radio button (from the Transport Connection Option section) to indicate you 

are connecting to the Master via a COM port.

6.

Click the 

Edit Settings

 button (on the 

Communications Settings

 dialog) to open the 

Serial 

Settings

 dialog and set the COM port parameters (used to communicate to the NetLinx 

Master). 

7.

Click the 

OK

 button three times to return to the main application.

8.

Right-click the entry in the 

Online Tree

 tab and select 

Refresh System.

9.

Assign a System Value by using 

Diagnostics

 > 

Device Addressing

 from the Main menu.

10.

Enable the 

Change System selection

 by clicking on it and then enter the current and new 

System values.

11.

Click the 

Change Device/System Number

 button and when finished click 

Done

.

12.

Select 

Tools

 > 

Reboot the Master Controller

 to access the 

Reboot the Master

 dialog, then 

click 

Reboot 

to restart the Master and incorporate any changes. 

13.

Once the dialog replies with "

Reboot of system complete

", click 

Done 

and then click the 

OnLine Tree

 tab in the Workspace window to view the devices on the System.

The default 

System value is one

.

14.

Right-click on the 

Empty Device Tree/System

 entry and select 

Refresh System 

to re-

populate the list.

Configuring the NI-900 for Ethernet Communication

Before continuing, complete the COM port steps above.
1.

Connect an Ethernet cable to the unit’s rear Ethernet connector.

2.

Select 

Diagnostics

 > 

Network Address

 from the Main menu and enter the System, Device 

(0 for a Master

), and Host Name information.

3.

To configure the Address:

Use a DHCP Address by selecting the 

Use DHCP

 radio button, then click the 

GET IP

 button 

(

to obtain a DHCP Address from the DHCP Server

), click the 

SET IP Information

 button (

to 

retain the new address

), and then finish the process by clicking the 

Reboot Master

 > 

OK

 

buttons.

Use a Static IP Address by selecting the 

Specify IP Address

 radio button, enter the IP 

parameters into the available fields, then click the 

SET IP Information

 button (

to retain the 

pre-reserved IP Address to the Master

), and then click the 

Reboot Master

 > 

OK

 buttons to 

finish the process.

4.

Repeat steps 1 - 5 from the previous section but rather than selecting the 

Serial

 option, 

choose

 TCP/IP

 and edit the settings to match the IP Address you are using (whether Static or 

IP).

5.

Click on the 

Authentication Required

 radio box (

if the Master is secure

d) and press the 

User Name and Password

 button to enter a valid username and password being used by 

the secured Master. 

6.

Click the 

OK

 button three times to return to the main application.

Additional Documentation

Additional Documentation for the NI-900 is available at www.amx.com:

Refer to the 

NI-700/900 Hardware Reference Guide

 for additional details on Installation, 

Upgrading, and Wiring the NI-900.

Refer to the 

NI Series NetLinx Integrated Controllers WebConsole & Programming Guide

 for 

detailed configuration instructions.

FIG. 2  

2-pin mini-Phoenix connector wiring diagram (direct power)

FIG. 3  

RS-232/422/485 DB9 (male) connector pinouts

FIG. 4  

Layout of Ethernet LEDs

PWR +

GND -

To the Integrated Controller

Power Supply

5

4
3

2

1

9
8

7

6

Male

DB9 Serial Port

 pinouts (male connector)

Pin 2: RX signal
Pin 3: TX signal
Pin 5: GND
Pin 7: RTS
Pin 8: CTS

RS-232

Pin 1: RX -
Pin 4: TX +
Pin 5: GND
Pin 6: RX +
Pin 9: TX -

RS-422

Pin 1: A (strap to 9)
Pin 4: B (strap to 6)
Pin 5: GND
Pin 6: B (strap to 4)
Pin 9: A (strap to 1)

RS-485

10/100

ETHERNET

SPD

L/A

SPD

 - Speed LED lights (yellow) when

and turns Off when the speed 
is 10 Mbps.

the connection speed is 100 Mbps

L/A

 - Link/Activity LED lights

(green) when the Ethernet

cables are connected and

 terminated correctly.

Baud Rate Settings

Baud Rate

Position 5

Position 6

Position 7

Position 8

9600 bps

OFF

ON

OFF

ON

38,400 bps (default)

OFF

ON

ON

ON

57,600 bps

ON

OFF

OFF

OFF

115,200  bps

ON

ON

ON

ON

Reviews: