Octaire Control Panel Operation
57
Octaire Instruction Manual
Locking & Unlocking
Locking the Octaire Control Panel prohibits access to the system and can prevent accidental switching.
While the panel is locked, BCS commands still work; however, they cannot be used to unlock the panel.
The panel remains locked if the power is cycled.
The password used to lock and unlock the panel consists of a sequence of five input keys. The factory
default password is the first five Input Keys (1-2-3-4-5). A new password can be set using any
combination of five keys from Input 1 through Input 8.
Important: We strongly recommend recording passwords in a secure place; the Octaire system
cannot retrieve a lost password.
If the password is lost while the system is locked, contact technical support (see page 31).
Locking the Control Panel
If you enter the wrong password while attempting to lock the Control Panel, the LCD displays “Invalid
Password” and the Cancel Key flashes. Press the Cancel Key to clear the error and enter the correct
password.
Note: For security purposes, the Input Keys do not turn white when pressed while locking and
unlocking the panel.
To lock the Control Panel:
1.
Press the Function Key.
The Function menu appears.
2.
Locate Lock Panel by scrolling with the Control Dial.
3.
Press the Select Key.
The system is in Lock Mode (Input Keys 1 through 8 turn blue).
4.
Press the Input Keys in the following order: 1, 2, 3, 4, 5 (default password).
The panel is locked, and all Input and Output Keys turn off.
Summary of Contents for Distribution Matrix Octaire
Page 1: ...Instruction Manual Matrix Switchers Octaire Distribution Matrix Release 08 15 2008...
Page 11: ...Notices 6 Octaire Instruction Manual...
Page 43: ...Installation Setup 38 Octaire Instruction Manual...
Page 47: ...Signal Types Specifications 42 Octaire Instruction Manual...
Page 71: ...Octaire Control Panel Operation 66 Octaire Instruction Manual...
Page 105: ...Appendix B Programmer s Interface for System Diagnostics 100 Octaire Instruction Manual...