Overview & General Specifications
10
Octaire Instruction Manual
Because the video enclosures look identical, it is crucial that they are cabled according to the labels on
the rear and the “Octaire AutoPatch Connector Guide” (see page 96), which is included in the shipment
(also see “Linking Enclosures” on
page 19).
Note: On a multi-enclosure system, the primary enclosure is the one with a control panel (and
a TCP/IP port) and is the point of control for the system.
Octaire Features
Ultra-Flat Response Certified (bandwidth curve measured at a tight +/-3 dB)
Ultra-wideband video bandwidth for UWB enclosures in any routing state, including fully
loaded – averaging 600 MHz, while maintaining 500 MHz at the ultra-flat response certified
minimum
High bandwidth-linearity and low crosstalk
Detection, Assignment, and Configuration (DAC) firmware that automatically recognizes and
configures each enclosure, sequences them, and generates a united, single feature solution
Switch any input to any or all outputs in any combination and disconnect any or all outputs
Breakaway to route video, audio, or audio-follow-video
Global presets
Vertical interval synchronization of video signals
Dual power feeds and redundant power supplies
Standard RS-232
Service Access Spacing (twice the space between connectors) –
making BNC cable
connections easy
Standard Warranty (see warranty at
www.amx.com
or on the
AMX AutoPatch CD
)
24-hour technical support
Octaire Control Features
In addition to the front control panel (standard with all Octaire systems), which is mounted on the
primary enclosure, several control options are available. Multiple control methods can be used on the
same system.
NetLinx
®
compatible and supports Device Discovery (for specific control programming
information, contact your AMX representative)
APControl 3.0 software (free with all systems)
APWeb (TCP/IP control)
Supports AMX AutoPatch’s simple BCS* (Basic Control Structure) serial control protocol
Supports AMX AutoPatch’s XNNet protocol
Supports third-party controllers
* BCS is sent as ASCII characters through the RS-232 port.
Important: Device Discovery functionality (beacon response) will only function properly if the
NetLinx master is connected to the RS-232 control port on the primary enclosure (the one with
the control panel). The RS-232 ports on the secondary enclosures are intended for single
enclosure diagnostic information and system firmware upgrades.
Features and specifications described in this document are subject to change without notice.
Summary of Contents for Distribution Matrix Octaire
Page 1: ...Instruction Manual Matrix Switchers Octaire Distribution Matrix Release 08 15 2008...
Page 11: ...Notices 6 Octaire Instruction Manual...
Page 43: ...Installation Setup 38 Octaire Instruction Manual...
Page 47: ...Signal Types Specifications 42 Octaire Instruction Manual...
Page 71: ...Octaire Control Panel Operation 66 Octaire Instruction Manual...
Page 105: ...Appendix B Programmer s Interface for System Diagnostics 100 Octaire Instruction Manual...