RDC-PDC Control Card, Dual or Three Phase

Connecting Dry Closures

Use the 8 (+ common) dry closures with a WPD8 eight-button wall panel.    

Each contact closure connection (1 - 8) is pre-programmed with a default 
preset. The table below shows the default presets for each contact clo-
sure.  

Setting AXlink and PROlink Address Numbers:  

Lighting Application Drawings   

 
   

     

FIG. 5  Dry closures connection

Dry Closure Default Presets

Contact Closure

Default Function

1

Channel 1 at 100% in 1 second

2

Channel 2 at 100% in 1 second

3

Channel 3 at 100% in 1 second

4

Channel 4 at 100% in 1 second

 

1

2

3

4

5

6

7

8 COM

Each contact (1 - 8) is pre-
programmed with a default preset.

Refer to the 

AMX Lighting Control

System

 instruction manual for 

details on dry closure default presets
and recording new presets.

Dry Closure Default Presets (Cont.)

5

Channel 5 at 100% in 1 second

6

Channel 6 at 100% in 1 second

7

Pack on (channels 1-6)

8

Pack off (channels 1-6

All other channels are undefined.

FIG. 6  Setting AXlink and PROlink address numbers.

AXlink Address

PROlink Address

Test

Set the AXlink address number
(1-255) for the RDC-DC. This
number must match the device
number in your Axcess program.

Use the PROlink DIP switch to set
the PROlink address number for the
RDC-DC (1-10).

Pin 8 on the PROlink DIP switch is
a test switch that turns all circuits on
to full.

FIG. 7  Method A

Method A

RDC-PDC/120, 3 Phase
6 dimmers, 0 switches

Summary of Contents for Control Card RDC-PDC

Page 1: ...ttings and pre sets from accidental recording put the jumper in the On position Caution Pre Installation Notes All Class 1 wiring must be connected to proper terminals All control wiring must be connected to proper terminals Disconnect power while installing or connecting the unit Keep the top and bottom air vents clear at all times Test loads for shorts before connecting Use low voltage wires wit...

Page 2: ...ch contact 1 8 is pre programmed with a default preset Refer to the AMX Lighting Control System instruction manual for details on dry closure default presets and recording new presets Dry Closure Default Presets Cont 5 Channel 5 at 100 in 1 second 6 Channel 6 at 100 in 1 second 7 Pack on channels 1 6 8 Pack off channels 1 6 All other channels are undefined FIG 6 Setting AXlink and PROlink address ...

Page 3: ...phase 120 208 VAC 4 wire G THREE PHASE 120 208 VAC 4W G PHASE A Controls Dimmers 1 and 4 PHASE B Controls Dimmers 2 and 5 PHASE C Controls Dimmers 3 and 6 Method D Three phase 120 208 VAC 5 wire G THREE PHASE 120 208 VAC 5W G PHASE A Controls Dimmers 1 and 4 PHASE B1 Controls Dimmer 5 PHASE B2 Controls Dimmer 2 PHASE C Controls Dimmers 3 and 6 ...

Page 4: ...anual s associated with your Product s 043 019 2193 8 01 2001 AMX Corporation All rights reserved The AMX logo is a trademark of AMX Corporation AMX Corporation reserves the right to alter specifications without notice at any time 3000 research drive richardson TX 75082 USA 469 624 8000 800 222 0193 fax 469 624 7153 technical support 800 932 6993 ...

Reviews: