8
Installation
Camrobotics
CAM-1000 Connector Pinouts
Pin
Function
8
POTS +
9
POTS -
10
Tilt POT wiper
11
POTS +
12
N/A
13
N/A
14
N/A
15
N/A
Make up a 3’ set of AXlink cables and bench test the system before installation.
Bench-testing involves completing connections and adjustments, then performing all
operating procedures to verify proper performance.
Connecting the CAM-1000 to the AXB-CAM
To connect the CAM-1000 and the lens to the AXB-CAM:
1.
Connect the CAM-1000 pan/tilt head and the lens to the AXB-CAM with
(optional) CC-REL cables or your own cable. (Refer to the
AXB-CAM Instruction
Manual
for additional information.)
2.
Connect the AXB-EM232 and the AXB-CAM to the AXP-DTC using a four-wire
AXlink cable and the supplied 15-pin D sub male connector. The AXP-DTC
supplies power across the AXlink cable to the AXB-EM232 and the AXB-CAM.
Figure 5 shows the connector and Figure 6 shows the pinouts of the 15-pin D
sub female connector on the back of the AXP-DTC.
Pin 1
Pin 9
Caution
In multiple camera applications
using a PS2.8 with the AXB-
CAM, do not connect the +12V
wire of AXlink to the AXB-CAM.
Figure 5
AXP-DTC connector