background image

AMX Limited Warranty and Disclaimer

AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for 

three (3) years from the date of purchase from AMX Corporation, with the following exceptions:

Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch 
overlay components that are warranted for a period of one (1) year.

Disk drive mechanisms, pan/tilt heads, power supplies, MX Series products, and KC Series products are 
warranted for a period of one (1) year.

Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year.

Software is warranted for a period of ninety (90) days.

Batteries and incandescent lamps are not covered under the warranty.

This warranty extends only to products purchased directly from AMX Corporation or an Authorized AMX Dealer.

AMX Corporation is not liable for any damages caused by its products or for the failure of its products to perform. 

This includes any lost profits, lost savings, incidental damages, or consequential damages. AMX Corporation is not 

liable for any claim made by a third party or by an AMX Dealer for a third party.

This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort 

claim (including negligence and strict product liability), a contract claim, or any other claim. This limitation of 

liability cannot be waived or amended by any person. This limitation of liability will be effective even if AMX 

Corporation or an authorized representative of AMX Corporation has been advised of the possibility of any such 

damages. This limitation of liability, however, will not apply to claims for personal injury.

Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or 

exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of 

the Limited Warranty may not apply. This Limited Warranty gives the owner specific legal rights. The owner may 

also have other rights that vary from state to state. The owner is advised to consult applicable state laws for full 

determination of rights.

EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX CORPORATION MAKES NO 

OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX CORPORATION 

EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY 

IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS 

LIMITED WARRANTY.

Summary of Contents for AXU-SPL4

Page 1: ...instruction manual Product Category AXU SPL4 Mini LCD Panel ...

Page 2: ... liability applies whether damages are sought or a claim is made under this warranty or as a tort claim including negligence and strict product liability a contract claim or any other claim This limitation of liability cannot be waived or amended by any person This limitation of liability will be effective even if AMX Corporation or an authorized representative of AMX Corporation has been advised ...

Page 3: ...umber 3 Adjusting the Contrast Potentiometer 3 Wiring 4 AXlink wiring 4 Setting Jumpers 4 Relay connections 4 Input Output connections 5 Preparing Connecting Captive Wires 5 Mounting Options 6 BB SPL4 Back Box Optional 6 Three gang wall box 7 Finished surface 7 Connecting to the Control System 11 Testing 11 Programming 13 Channels 13 Send_String 13 Send_Commands 14 ...

Page 4: ...ii AXU SPL4 Mini LCD Panel Table of Contents ...

Page 5: ... A two position jumper next to each relay selects Normally Open NO default setting and Normally Closed NC operation Remove the jumper and insert over the NC pin for NC operation LED Indicators Green LED on rear panel lights to indicate AXlink status One blink per second power is active and AXlink communication is functioning Two blinks per second devices specified in the master program do not matc...

Page 6: ...Introduction 2 AXU SPL4 Mini LCD Panel ...

Page 7: ...tch shown above is set as device number 18 2 16 18 Adjusting the Contrast Potentiometer An adjustable contrast potentiometer is located under the cover plate and left of the four LED pushbuttons Use a Phillips head screwdriver to turn the potentiometer to the left or right to adjust LCD contrast The contrast potentiometer can be accessed via a hole in the back plate located to the top left of the ...

Page 8: ...mper FIG 3 next to each relay selects Normally Open NO default setting and Normally Closed NC operation Remove the jumper and insert over the NC pin for NC operation Relay connections Connect up to two independent external relay devices to the 4 pin Relay connector shown in FIG 4 Use A for common and B for output Each relay is isolated and normally open FIG 2 AXlink wiring FIG 3 Jumpers FIG 4 P2 R...

Page 9: ...r an output each I O port acts as a switch to GND and is rated at 200 mA 12 VDC PWR 12 VDC power output for I O type equipment I O 1 2 Two I O ports GND Common ground shared with I O ports 1 2 Preparing Connecting Captive Wires 1 Strip 0 25 inch of wire insulation off all wires 2 Insert each wire into the appropriate opening on the connector according to the wiring diagrams and connector types des...

Page 10: ... 3 Mount the BB SPL4 to the wall using wood screws metal screws or the supplied expansion screws 4 Remove the standard back box from the AXU SPL4 FIG 6 Drawing and dimensions of the BB SPL4 back box BB SPL4 Back Box Dimensions Item Inch mm Item Inch mm A 6 78 172 21 E 5 67 144 02 B 4 50 114 30 F 3 05 77 47 C 0 31 7 87 G 1 10 27 94 D 2 50 63 50 H 0 35 8 89 J Optional tab cutout for BB SPL4 installa...

Page 11: ...cm x 5 08 cm 2 Attach the panel to the three gang wall box using machine screws 3 Insert the cover plate into the magnetic bezel Finished surface To mount the AXU SPL4 to a finished surface 1 Cut out the finished surface according to the cutout dimensions in FIG 6 2 Place the panel over the cutout and mark the screw positions 3 Attach the panel to the finished surface using wood or machine screws ...

Page 12: ...7 demonstrates how to install the AXU SPL4 into sheetrock using OLD WORK expansion clips The expansion clips provide permanent installation allowing for easy removal for servicing FIG 7 Installing the AXU SPL4 into sheetrock using OLD WORK expansion clips ...

Page 13: ... SPL4 Mini LCD Panel FIG 8 demonstrates how to permanently install the back box with the face frame into a solid surface such as a podium or desk FIG 8 Installing the AXU SPL4 face frame and back box permanently into a hard surface ...

Page 14: ...4 Mini LCD Panel FIG 9 demonstrates how to install the AXU SPL4 face frame and back box into a hard surface podium desk as a single assembly FIG 9 Installing the AXU SPL4 face frame and back box into a hard surface as a single assembly ...

Page 15: ...link LED should blink once per second 3 The LCD will display AMX AXU SPL4 The display will change if any text functions are preprogrammed in the Axcess system Testing Connect a computer equipped with Axcess software to an Axcess CardFrame or Control System master port and perform the following 1 Press an LED pushbutton on the panel The LCD should display text as programmed 2 Verify proper LED push...

Page 16: ...Installation and Wiring 12 AXU SPL4 Mini LCD Panel ...

Page 17: ...le channel is ON relay 1 energized everything else is OFF 2 Pushbutton 2 254 Input Output Port 2 While channel is ON relay 2 energized everything else is OFF 3 Pushbutton 3 251 Relay 1 While channel is on I O 1 is on switch to GND everything else OFF 4 Pushbutton 4 252 Relay 2 While channel is on I O 2 is on switch to GND everything else OFF Orientation of the pushbuttons are from left to right AX...

Page 18: ...is command sets the backlight to full brightness SEND_COMMAND SPL4 LIGHT This command turns the backlight OFF OFFSET Sets the offset for the four pushbutton switches Default is 1 Syntax OFFSET Switch offset Example SEND_COMMAND SPL4 OFFSET97 This command sets the first switch left most to use channel 97 Switch 1 will be channel 97 for its PUSH RELEASE and feedback channel Similarly switch 2 throug...

Page 19: ...Programming 17 AXU SPL4 Mini LCD Panel ...

Page 20: ...ve richardson TX 75082 USA 469 624 8000 800 222 0193 fax 469 624 7153 technical support 800 932 6993 037 004 1053 11 01 2001 AMX Corporation All rights reserved AMX the AMX logo the building icon the home icon and the light bulb icon are all trademarks of AMX Corporation AMX reserves the right to alter specifications without notice at any time In Canada doing business as Panja Inc ...

Reviews: