background image

AMX Limited Warranty and Disclaimer

AMX warrants its products to be free of defects in material and workmanship under normal use for three (3) years from 
the date of purchase from AMX, with the following exceptions:

Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch 
overlay components that are warranted for a period of one (1) year.

Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one 
(1) year.

AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting 
products, as long as the AMX Lighting products are under warranty. AMX does guarantee the control of dimmable 
loads that are properly connected to our lighting products. The dimming performance or quality cannot be 
guaranteed due to the random combinations of dimmers, lamps and ballasts or transformers.

Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year.

AMX Software is warranted for a period of ninety (90) days.

Batteries and incandescent lamps are not covered under the warranty.

This warranty extends only to products purchased directly from AMX or an Authorized AMX Dealer.

All products returned to AMX require a Return Material Authorization (RMA) number. The RMA number is obtained 
from the AMX RMA Department. The RMA number must be clearly marked on the outside of each box. The RMA is 
valid for a 30-day period. After the 30-day period the RMA will be cancelled. Any shipments received not consistent 
with the RMA, or after the RMA is cancelled, will be refused. AMX is not responsible for products returned without a 
valid RMA number.

AMX is not liable for any damages caused by its products or for the failure of its products to perform. This includes any 
lost profits, lost savings, incidental damages, or consequential damages. AMX is not liable for any claim made by a 
third party or by an AMX Dealer for a third party.

This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort claim 
(including negligence and strict product liability), a contract claim, or any other claim. This limitation of liability cannot 
be waived or amended by any person. This limitation of liability will be effective even if AMX or an authorized 
representative of AMX has been advised of the possibility of any such damages. This limitation of liability, however, will 
not apply to claims for personal injury.

Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or 
exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of 
the Limited Warranty may not apply. This Limited Warranty gives the owner specific legal rights. The owner may also 
have other rights that vary from state to state. The owner is advised to consult applicable state laws for full 
determination of rights.

EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX MAKES NO OTHER WARRANTIES, 
EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR 
A PARTICULAR PURPOSE. AMX EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED 
WARRANTY. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF 
THIS LIMITED WARRANTY.

Summary of Contents for AXP-CPI16

Page 1: ...Operation Reference Guide Custom Panel Interfaces AXP CPI16 16 Channel Custom Panel Interface Document ID 038 004 1334 Last Revised 8 16 2006 ...

Page 2: ... or after the RMA is cancelled will be refused AMX is not responsible for products returned without a valid RMA number AMX is not liable for any damages caused by its products or for the failure of its products to perform This includes any lost profits lost savings incidental damages or consequential damages AMX is not liable for any claim made by a third party or by an AMX Dealer for a third part...

Page 3: ...formation 1 Specifications 1 Installation 5 Mounting Dimensions 5 Setting the AXlink Device Number 6 Preparing connecting captive wires 6 Connecting the Two 20 pin Headers 6 Switch Wiring Diagrams 7 Connecting the AXlink Wiring 7 Programming 9 Testing the Unit 10 AXP CPI16 System Worksheet 11 ...

Page 4: ...ii AXP CPI16 16 Channel Custom Panel Interface Table of Contents ...

Page 5: ...4 50 mm x 1 557 mm Power Input voltage 12 VDC nominal Current draw 25mA Inputs 16 closure inputs with a common ground GND Outputs 16 open collector outputs acting as switch to ground up to 100 mA DC each for Board is not to supply more than 750 mA of 12V total Small incandescent lamps LED indicators with series resistor 1K for 12 VDC Relays with DC coil AXlink Connector A 4 pin male connector atta...

Page 6: ...ng Two blinks per second devices specified in the master program do not match the specified devices found Three blinks per second indicate an AXlink communication error Full on indicates there is no AXlink control or activity but power is on or the Axcess program is not loaded Device DIP Switch 8 position DIP switch sets AXlink device ID Cables Two 3 foot 91 4 cm ribbon cables each with a female 2...

Page 7: ...Product Information 3 AXP CPI16 16 Channel Custom Panel Interface 1 2 3 4 5 6 7 8 ON OFF OFF ON ...

Page 8: ...Product Information 4 AXP CPI16 16 Channel Custom Panel Interface ...

Page 9: ...al spacing B 1 75 44 50 L 0 125 Inch 3 2 mm mounting holes for 4 40 3 mm screws C 1 55 39 40 M P3 20 Pin Header 025 inch 6 mm square pins 1 inch 2 4 mm typical spacing D 2 75 69 90 E 2 55 64 80 F 0 35 8 90 G 0 23 5 80 H 0 438 11 10 J 0 93 23 6 L H F 2 1 E G P2 20 19 Component Side AXP AXlink D A PWR A Top View P1 AXM GND B C K J min P3 M 1 2 19 20 E D F A A B C L M Top View Component Side K G H mi...

Page 10: ... to secure the wires Do not tighten the screws excessively doing so may strip the threads and damage the connector Connecting the Two 20 pin Headers The following chart notes the pinouts of the two 20 pin headers for P2 and P3 Pin 10 provides 12 VDC power from AXlink bus Add 1K series resistors when using AXP CPI16 with LED indicators receiving 12 VDC power from Pin 10 Position 1 2 3 4 5 6 7 8 Val...

Page 11: ...all four wires If the wire is 20 AWG or less fold the exposed wire over to obtain a positive connection 2 Insert each wire into the appropriate opening on the connector as shown in FIG 3 3 Tighten the screws to secure the fit FIG 2 LED and switch wiring diagrams FIG 3 AXlink wiring diagram 3 LED 3 LED 2 10 LED 1 1 2 1K 1K 1K LED Wiring Typical SW 3 15 SW 1 SW 2 12 13 14 Switch Wiring Typical PWR A...

Page 12: ...Installation 8 AXP CPI16 16 Channel Custom Panel Interface ...

Page 13: ...rogrammer to monitor the status of an output channel However the channel offset must be accommodated in the programming code Statements such as this example can be used in a program IF CPI16 25 output channel assigned to input channel 9 on P3 connector Each of the two 20 pin connectors is assigned a group of 8 input and output channels The table below shows the relation of input and output channel...

Page 14: ...e program into a PC connected to the control system Master port See Programming on page 4 1 Push switches connected to the AXP CPI16 2 Look at the lower left of the Axcess screen to verify that the correct device and channel numbers are displayed 3 Check for the appropriate feedback as provided by the Master Controller program ...

Page 15: ...mber Description Serial Number Rev Number Device Number 4 3 2 1 15 16 4 3 14 2 13 1 6 5 18 6 17 5 8 7 20 8 19 7 Out In Out In Out In Out In Out In Out In Out In Out In 12 VDC PWR GND N C N C 12 10 11 9 Channel Pin Number 20 PIN HEADER HEADER P2 FUNCTION Out In Out In Out In Out In Out In Out In Out In Out In N C N C 12 VDC PWR GND Pin Number ...

Page 16: ...9 15 16 4 3 14 2 13 1 14 13 18 6 17 5 16 15 20 8 19 7 Out In Out In Out In Out In Out In Out In Out In Out In 12 VDC PWR GND N C N C 12 10 11 9 Channel Pin Number 20 PIN HEADER HEADER P3 FUNCTION Pin Number Out In Out In Out In Out In Out In Out In Out In Out In N C N C 12 VDC PWR GND ...

Page 17: ...System Worksheet 13 AXP CPI16 16 Channel Custom Panel Interface ...

Page 18: ...o are registered trademarks of AMX AMX reserves the right to alter specifications without notice at any time It s Your World Take Control 3000 RESEARCH DRIVE RICHARDSON TX 75082 USA 800 222 0193 469 624 8000 469 624 7153 fax 800 932 6993 technical support www amx com ...

Reviews: