Upgrading the Firmware
70
AXB-TPI/3 Touch Panel Interface 3
3.
Press the
NetLinx
radio button from within the Platform section of the Communication
Settings dialog box (FIG. 17).
4.
From the Communications Port drop-down list, choose
Network
. This indicates the
IP Address on the master is being reached from within a network connection.
5.
Enter the IP Address information displayed on the
Networking
tab.
Do not alter the defaulted
IP port.
6.
Click the
OK
button to end the process of obtaining and assigning the IP Address to the
NetLinx Master.
7.
Select
Edit
>
Preferences
, from the
General - Communications
section
8.
Select the
Enable Online Tree
option to view the Connected devices from within the Project
Navigator window. The next step is to set the System value.
9.
After the Communication Verification dialog window verifies active communication between
the PC, the Master and the TPI/3, verify the Touch Panel Interface appears in the Online tab of
the Project Navigator window (FIG. 18).
10.
Right-click on the Touch Panel Interface Device value and select Properties to confirm the
on-board firmware.
FIG. 17
Communication Setting tab
FIG. 18
Sample NetLinx Project Navigator window
Enter an IP Address
Summary of Contents for AXB-TPI/3
Page 6: ...iv AXB TPI 3 Touch Panel Interface 3 Table of Contents ...
Page 32: ...TPI Configuration and Usage 26 AXB TPI 3 Touch Panel Interface 3 ...
Page 72: ...Programming 66 AXB TPI 3 Touch Panel Interface 3 ...
Page 80: ...Upgrading the Firmware 74 AXB TPI 3 Touch Panel Interface 3 ...
Page 84: ...Troubleshooting 78 AXB TPI 3 Touch Panel Interface ...