Installation
8
6" Color Video Touch Panels
Installing the AXD into a flat or solid surface
To install AXD-CV6 touch panels:
1.
Remove the magnetically attached Decor faceplate (
A
in FIG. 6
)
from the main AXD unit
(
B
in FIG. 6) by gripping the faceplate and pulling with gentle force.
2.
Cut out the surface using the dimensions shown in FIG. 7. Be sure not to cut out notches for the
expansion clips (only used when mounting the panel in plasterboard). FIG. 8 shows a sample
of the CV6 (
62-5924-06
) cutout template used for an accurate visual reference of the cutout
dimensions.
3.
Thread the incoming AXlink wiring through the cutout on the flat surface.
4.
Disconnect the AXlink connector from the Central Controller and thread the terminal end of
the 4-pin AXlink cable through the circular cable knockouts provided on the wallbox.
5.
Attach the data and power wiring to the touch panel.
6.
Test the connection by reconnecting the AXlink connector to the Central Controller. Verify that
the panel is receiving power and functioning properly to prevent repetition of the installation.
7.
Disconnect the AXlink connector from the Central Controller until installation is complete.
8.
Connect the data and power wiring to the rear of the touch panel.
9.
Insert the main unit into the flat surface mounting until firmly positioned and flush with the
surface battery.
10.
Fasten the main AXD unit to the surface using the four surface-screws (#4 screws) supplied
with the enclosure (FIG. 9).
11.
Place the magnetic Decor faceplate (
A
in
FIG. 9) onto the main AXD unit (
B
in
FIG. 9) by
gripping the faceplate and placing it on with gentle force.
FIG. 6
Wall Mount panel installation configuration for flat /solid surfaces
A
B
- Main AXD unit consists of
- Decor
faceplate
Install the #4-40
Solid surface
(can include a
the touch panel and housing
wall, podium, or
other level
surface)
machine screws
into the holes
shown below.
Screw length
depends on the
installation surface.
These 4 screws
are removed
to access or
replace the
battery.