background image

 
IP Control Unit Installation Guide V1.1 
12

th

 February 2008 

 

2.2 Using the loop through facility 

 
The 8450-02 / 8460-02 have dual loop through facility available allowing the IP Control Unit to sit in the 
middle of an existing connection between devices.  Any RS232 received on the Loop of port 2 is sent straight 
out of the TX of port 2 and likewise anything received on the loop of port 3 gets sent out of port 3.   
 
 

 

2.3 Example installation 

 
Figure 2.3 shows and example installation correctly wired to maximise the potential of the IP Control Unit.  
You will see that the way the setup is connected, the control panel makes use of both loop through paths in 
order to allow local control of the projector and switcher with the IP Control Unit still having full access to the 
devices for remote control. 
 

 

Figure 2.3 Example installation correctly wired to maximise system potential 

 
 
 
 
 
 
 
 
 
 
 
 

www.amx.com 

- 4  -

Summary of Contents for 8450-02

Page 1: ...Control Units 8450 03 3 port version 8455 03 1 port version 8460 03 3 port version with real time clock 8465 03 1 port version with real time clock 8701 control system with IP interface Installation Guide ...

Page 2: ...nit via a crossover cable 5 3 2 Connecting the Control Unit to a network with a DHCP server 7 3 3 Connecting the Control Unit using a static IP address single subnet network 8 3 4 Connecting to a network with multiple subnets 9 Appendix A Troubleshooting 10 A 1 I have connected my Control Unit but can t see it in Site Manager 10 A 2 The interface has not picked up the correct IP address via DHCP 1...

Page 3: ...tor needs changing Projector lamp expiration alert uses one of the timers sends an e mail to notify that a projector lamp has passed a preset duration and needs changing requires Site Manager software to be running Built in scheduling that operates from the onboard clock allowing events to occur without Site Manager software 8450 02 8455 02 8460 02 8465 02 8701 03 Number of RS232 ports 3 1 3 1 2 L...

Page 4: ...2 signals received will be transmitted back out of Port 2 See section on interface operations Port 2 See Port 1 for connection to the second RS232 device Loop This port is input only and any RS232 signals received will be transmitted back out of Port 3 See section on interface operations Port 3 See Port 1 for connection to the third RS232 device 8455 8465 Connections Item Description CL A connecti...

Page 5: ...wise anything received on the loop of port 3 gets sent out of port 3 2 3 Example installation Figure 2 3 shows and example installation correctly wired to maximise the potential of the IP Control Unit You will see that the way the setup is connected the control panel makes use of both loop through paths in order to allow local control of the projector and switcher with the IP Control Unit still ha...

Page 6: ...rk Connections Select Local Area Connection Right Click and Select Properties Click Internet Protocol TCP IP Select Properties Select the first option Obtain An IP Address Automatically If there is a tab at the top saying Alternate Configuration select it and select the option Automatic Private IP Address Now connect the IP Control Unit to the computer using a crossover cable and you will see this...

Page 7: ...lick Add Building Click Add Room From IP Device with the Site List Click Add Interface The IP Control Unit should be present in the list Double Click the Interface Click Done The IP Control Unit is now ready for use symbolised by the green ticks For more information on using the Site Manager software please refer to the instruction manual www amx com 6 ...

Page 8: ... problems as the IP Control Units could assign themselves an address which would then be in conflict with other devices It is essential that this is resolved before installing the interfaces The IP Control Unit is delivered pre configured to acquire its network information from a DHCP server Connect the interface to a suitable network port using a standard network patch cable and then apply power ...

Page 9: ...ice Click No Enter the desired IP address After a few seconds the IP Control Unit will re appear in the window with the new IP address and can be added to your Site List If you use this method you must go into the properties of the device afterwards and select properties re type the IP address and click Update Settings 2 The second method is to connect the device using a crossover cable see instru...

Page 10: ...fault gateway Unless the DHCP server gives the IP Control Unit a fixed IP address there is the possibility of it being given a different IP Address after a power or network failure and the Site Manager software will show the IP Control Unit as being offline because the properties are now different It is recommended that if a DHCP server is used then it assigns the IP Control Unit a fixed IP addres...

Page 11: ...et the power to the interface and try again Check with the network administrator as to whether or not the MAC address of the interface needs to be registered with the DHCP server before it will assign it an address A 3 The link light does not light when the network cable is inserted Try using a different cable there may be a broken wire in it Check the network port by plugging in a PC to make sure...

Page 12: ...IP Control Unit Installation Guide V1 1 12 th February 2008 Appendix B Revision History Date Revision Notes 20 06 05 1 0 First release 12 02 08 2 0 Updated for V3 interfaces www amx com 11 ...

Reviews: