Amway Atmosphere Sky Owner'S Manual Download Page 8

6

Atmosphere Sky

 Owner’s Guide

Cleaning the Pre-Filter 

1.  Power off and unplug the unit.
2.  Remove the front cover of the unit by placing your fingertips under 

the upper most edge of the front shield, gently pull up on the shield to 
disengage (should hear snap) then lift the shield off the unit. Magnets at 
the bottom of the shield will release on their own.

3.  Remove the Pre-Filter by lifting from the tabs located at the top of the 

filter screen.

4.  Remove accumulated dust from the Pre-Filter with a vacuum cleaner.  If 

the filter is very dirty rinse with warm tap water.  Dry thoroughly before 
replacing in the unit.

5.  Reattached the Pre-Filter by placing the slots at the top of the filter to 

the tabs on the top of the HEPA filter.

6.  Replace the front shield by positioning the shield over the display and 

let it gently fall into place engaging the magnets on the bottom of the 
shield.  Then gently push until you hear a soft snap at the middle of the 
shield at the upper most edge of the display 

7.  Plug in your unit.
8.  Reset the Pre-Filter by pushing the Pre-Filter light on the display. The 

Pre-Filter monitor light will change from red to green.

 
 
Replacing the HEPA Filter

1.  Power off and unplug the unit.
2.  Remove the front cover of the unit by placing your fingertips under 

the upper most edge of the front shield, gently pull up on the shield to 
disengage (should hear snap) then lift the shield off the unit.

3.  Remove the Pre-Filter/HEPA by disengaging the lock at the top of the 

HEPA Filter.  

4.  Gently lift the Pre-Filter from the HEPA Filter by lifting from the tabs 

located at the top of the filter screen. Set the Pre-Filter aside; you may 
want to clean your Pre-Filter at this time even if the light is green.

5.  Remove your new HEPA Filter from the packaging.
6.  Install your new HEPA filter into your unit, reengage the lock at the top 

of the filter.

7.  Reattached the Pre-Filter by placing the slots at the top of the filter to 

the tabs on the top of the HEPA filter.

8.  Replace the front shield by positioning the shield over the display and 

let it gently fall into place engaging the magnets on the bottom of the 
shield.  Then gently push until you hear a soft snap at the middle of the 
shield at the upper most edge of the display 

9.  Plug in your unit.
10. The HEPA Filter monitor light will automatically change from red  

to green.

 

Maintenance 

Your Atmosphere Sky

 Air Treatment System should be cleaned and maintained regularly for  

optimum performance.

As Needed

Wipe the housing exterior with a damp cloth and dry.  If very dirty, use a mild detergent, such as  
L.O.C.

 Multi-Purpose Cleaner.  Do not use cleaners containing ammonia, alcohol, or paint thinner.   

These cleaners will damage the surface.

Locked

Unlocked

Summary of Contents for Atmosphere Sky

Page 1: ...Owner s Guide Atmosphere Sky Air Treatment System ...

Page 2: ...phere Sky Air Treatment System comes pre installed with three filters the pre filter HEPA and carbon filter Inside the box you ll also find the power cord for the unit ENGLISH 01 08 01 04 02 03 04 06 03 07 Product Visuals Limited Warranty Get Started Service and Replacement Parts Important Safeguards 3rd Party Certifications Product Features Maintenance Troubleshooting Customer Service Table of Co...

Page 3: ...Remove the protective wrap on filters Avoid completing this step on carpet or a light colored surface as carbon dust may fall from the filters 4 Follow instructions on Registration Label to register your unit 5 Reinstall the filters ensuring the lock on the HEPA filter is secure and reattach the front shield 6 Place the unit in the room where it will be used near an electrical outlet and away from...

Page 4: ...only 4 Do not allow liquids or any objects in any of the unit openings Keep openings free of excessive dust lint hair or debris that may reduce the air flow 5 Do not expose the unit to rain and do not use in a wet area Do not place the unit near a bathtub or a kitchen sink 6 Do not unplug the unit by pulling on the cord To unplug the unit grasp the plug itself and pull gently 7 Do not operate with...

Page 5: ...ov Troubleshooting Condition Solution The operation light is on but air does not come out of the unit Check that the protective shipping bags are removed from the filters inside the unit Dirt and or pet hairs can build up on the pre filter To wash and reinstall the pre filter Turn off the power and unplug the unit Remove the front shield from the unit Remove the pre filter from the unit Thoroughly...

Page 6: ...air circulation system The dual part Intelliflow Assembly directs the air flow inside the unit moving air in a pattern that minimizes resistance and noise and maximizes air flow Performance Features Effectively removes 99 99 of particles as small as 0 007 microns in size from air passing through the unit Effectively reduces unpleasant odors such as tobacco cooking and pet odors CADR measures no le...

Page 7: ... price and applicable tax Other restrictions apply For more information visit www amway com and search Satisfaction Guarantee 5 The app Atmosphere Connect works like a remote control for the unit Download the free app to your smart phone or mobile device and use it when you re at home or away to Adjust the settings Monitor the status of the filters Check your room s air quality Atmosphere Connect ...

Page 8: ... your fingertips under the upper most edge of the front shield gently pull up on the shield to disengage should hear snap then lift the shield off the unit 3 Remove the Pre Filter HEPA by disengaging the lock at the top of the HEPA Filter 4 Gently lift the Pre Filter from the HEPA Filter by lifting from the tabs located at the top of the filter screen Set the Pre Filter aside you may want to clean...

Page 9: ...n information such as how to s tracking information and processing fees Track your return with an Amway return label at returnscenter smartlabel com amway For all returns Amway Independent Business Owners are charged a 5 95 processing fee per invoice Any merchandise returned due to errors or damages upon delivery will not incur a processing fee We are not liable for return merchandise that doesn t...

Page 10: ...tachments not recommended by the manufacturer may result in diminished performance Amway does not warrant the performance of any non Atmosphere Sky Air Treatment System parts or accessories not authorized by Amway or the manufacturer for use with the Unit and Amway is not responsible for any damage caused by or resulting from the use of any non authorized parts or accessories WHAT WILL AMWAY DO IF...

Page 11: ...mplied warranty lasts so the above limitations may not apply to you This Limited Warranty gives you specific legal rights and you may also have other rights which vary from state to state or province to province The laws of some jurisdictions do not permit the exclusion or limitation of certain rights or remedies As this Limited Warranty is subject to those laws some of the limitations or restrict...

Page 12: ... Alticor Inc 1045062 EPA EST 6718 MI 001 Exclusively by ...

Reviews: