![AMW 100 Installation Manual Download Page 9](http://html.mh-extra.com/html/amw/100/100_installation-manual_2937381009.webp)
AMW 12_00
5
C
C
O
O
M
M
P
P
O
O
S
S
I
I
T
T
I
I
O
O
N
N
H
H
O
O
U
U
S
S
I
I
N
N
G
G
Zinc plates painted in epoxy RAL 7011.
Internal plates in epoxy painted zinc plates and galvanized plates.
The panels are secured with self-tapping screws and sanitary washers.
The maintenance panel – behind which the air filter is installed – should always remain accessible.
Sound-absorbing and flame extinguishing 20 mm thick insulation (NEN-EN 13501-1:2002).
I
I
D
D
E
E
N
N
T
T
I
I
F
F
I
I
C
C
A
A
T
T
I
I
O
O
N
N
L
L
A
A
B
B
E
E
L
L
Each unit bears a self-adhesive identification label on the back.
This label mentions besides the type of unit, its serial number and technical data.
N
N
E
E
V
V
E
E
R
R
R
R
E
E
M
M
O
O
V
V
E
E
T
T
H
H
E
E
I
I
D
D
E
E
N
N
T
T
I
I
F
F
I
I
C
C
A
A
T
T
I
I
O
O
N
N
L
L
A
A
B
B
E
E
L
L
:
:
T
T
H
H
E
E
G
G
U
U
A
A
R
R
A
A
N
N
T
T
E
E
E
E
W
W
I
I
L
L
L
L
E
E
X
X
P
P
I
I
R
R
E
E
.
.
C
C
O
O
O
O
L
L
I
I
N
N
G
G
C
C
I
I
R
R
C
C
U
U
I
I
T
T
Hermetically sealed compressor with R407C, vibration-free fitted and cooled with suction gas
Evaporator and condenser battery with copper pipes (3/8”) with pressed-on aluminium plates, coated with
epoxy varnish
ABS condensation tank
Expansion valve with distribution head for several injections
Combi-dryer: combination of filter, dryer, sight-glass and liquid reservoir
High and low pressure thermostats
Electronic control with shut-off at LP, HP, TC and TF *
* LP = low pressure HP = high pressure TC = thermal contact compressor TF = thermal contact fan
The cooling circuit is pre-filled with Forane 407C, which is a CFC-free coolant which does not damage the ozone
layer and does not influence the breeches shaft effect.
The diagram below shows the composition of one cooling circuit and optional swimming pool condenser, indicating
the different components.
(1) Compressor
(2) Evaporator
(3) Condenser
(4) Expansion valve
(5) Combi dryer
(6) Sight-glass
(7) HP pressure gauge
(8) LP pressure gauge
(K) Swimming pool condenser
C
C
O
O
O
O
L
L
I
I
N
N
G
G
C
C
I
I
R
R
C
C
U
U
I
I
T
T
S
S
W
W
I
I
T
T
H
H
O
O
U
U
T
T
S
S
I
I
D
D
E
E
C
C
O
O
N
N
D
D
E
E
N
N
S
S
E
E
R
R
S
S
A
A
R
R
E
E
S
S
E
E
A
A
L
L
E
E
D
D
A
A
N
N
D
D
A
A
R
R
E
E
F
F
I
I
L
L
L
L
E
E
D
D
W
W
I
I
T
T
H
H
N
N
I
I
T
T
R
R
O
O
G
G
E
E
N
N
I
I
N
N
T
T
H
H
E
E
F
F
A
A
C
C
T
T
O
O
R
R
Y
Y
.
.
A
A
F
F
T
T
E
E
R
R
A
A
S
S
S
S
E
E
M
M
B
B
L
L
Y
Y
T
T
H
H
E
E
Y
Y
S
S
H
H
O
O
U
U
L
L
D
D
B
B
E
E
F
F
I
I
L
L
L
L
E
E
D
D
W
W
I
I
T
T
H
H
F
F
O
O
R
R
A
A
N
N
E
E
R
R
4
4
0
0
7
7
C
C
.
.
C
C
A
A
U
U
T
T
I
I
O
O
N
N
:
:
T
T
H
H
E
E
Y
Y
A
A
R
R
E
E
P
P
R
R
E
E
S
S
S
S
U
U
R
R
I
I
Z
Z
E
E
D
D
.
.
Summary of Contents for 100
Page 1: ......
Page 2: ......
Page 4: ......
Page 8: ......
Page 18: ...14 AMW 12_00 I IN NS ST TA AL LL LA AT TI IO ON N E EX XA AM MP PL LE E ...