INSTALLING AN OIL SAMPLING PETCOCK
ON THE SPIN-ON BY-PASS:

Getting a clean and uncontaminated oil
sample is easy and simple when an oil
sampling pet-cock is installed into the Spin-
On By-Pass Oil Filter system. This can be
easily done by ordering a BK-13. 
Installs in place of the BP-191 Allen Head
Plug.

1. Provide for length change

In straight hose installations allow enough slack in
the hose line to provide for changes in length that will
occur when pressure is applied. This change in length
can be from +2% to -4%.

RIGHT

WRONG

4. Avoid mechanical strains

Use elbows and adapters in the installation to relieve
strain on the assembly, and to provide easier and
neater installations that are accessible for inspection and
maintenance.

WRONG

RIGHT

7. Secure for protection

Install hose runs to avoid rubbing or abrasion. Use clamps to support long runs
of hose or to keep hose away from moving parts. It is important that the clamps
do not allow the hose to move. This movement will cause abrasion and pre-
mature hose failure.

RIGHT

WRONG

8. Avoid Improper Hose Movement

Make sure relative motion of the machine components produces bending rather than twist-
ing of the hose. Hose should be routed so that the flex is in the same plane as the equipment
movement.

RIGHT

WRONG

5. Use proper bend radius

Keep the bend radius of the hose as large as possible
to avoid collapsing of the hose and restriction of flow.
Follow catalog specs on minimum bend radii.

RIGHT

WRONG

6. Use proper bend radius (cont.)

Maximum bend radius is measured on the inside bend
of the hose. To determine minimum bend, divide the
total distance between ends (B length) by 2. For exam-
ple B = 6, minimum bend radius = 3.

3.00

RADIUS

6.00

DIAMETER

B

2. Avoid twisting and orient properly

Do not twist hose during installation. This can be deter-
mined by the printed layline on the hose. Pressure
applied to a twisted hose can cause hose failure or
loosening of connections.

RIGHT

WRONG

3. Protect from hazardous environment

Keep hose away from hot parts. High ambient temper-
atures will shorten hose life. If you can not route it
away from the heat source, insulate it.

WRONG

RIGHT

Diagram G

Oil Analysis:

1. If installing By-Pass Oil Filter with AMSOIL Air Filter and 100% Synthetic Engine Oil in a

pleasure vehicle, we recommend the TRIGARD Oil Analysis Program:

a. TRIGARD 1 (Stock No. ATG-01) is the starter program. It contains material for reg-

istration and 2 

prepaid

analysis to check oil’s condition.

b. TRIGARD 2 (ATG-02) is for all subsequent oil samples. Each ATG-02 also contains

materials for 2 prepaid oil analysis.

2. For other oil analysis order G-1318 Oil Analysis Sampling Kits (in U.S., Canada). Consult

AMSOIL Technical Service for details.

AMSOIL INC., AMSOIL Bldg., Superior, WI (715) 392-7101

BP-174   8/06

To order By-Pass Oil Filter Parts or oil sample kits, consult your AMSOIL Dealer or the AMSOIL Product Price List for your country.

Most of these items are available from your AMSOIL Product Center.

BP174 83642  8/23/06  8:22 AM  Page 4

Summary of Contents for BMK-15Ea

Page 1: ...trol any loss of oil remove the existing engine full flow oil filter Clean the gasket seating area on the engine with a clean lint free cloth 3 Install the spin on filter adapter in place of the old oil filter To ensure proper sealing and aid in installation place a small amount of grease on both sides of the O ring used Tighten the adapter one full turn after adapter first contacts sealing surfac...

Page 2: ... to higher oil contamination levels in diesel engines and variance in fuel quality maintenance intervals for the filter ele ment and oil change intervals should be determined using oil analysis For more on oil analysis see the last page 8 7 9 10 11 7 6 11 7 1 6 8 7 O U T I N 17 16 2 12 15 5 13 4 14 14 14 3 3 3 14 4 5 EaBP 100 10 101 4 Ea0 26 5 9 Diagram A MINIMUM AREA NEEDED FOR DUAL MOUNT AND SPI...

Page 3: ... ANGLE HORIZONTAL 0 20 50 130 160 180 Mounting Angle Diagram C Recommendations are the same right to left and front to back Mounting angle above horizontal is not recommended 15 16 1 3125 25 21 4 1 4 2 25 Diagram F 2 Oil inside of hose and nipple threads liberally with oil Do not oil hose cover 3 Screw nipple assembly into socket using wrench on nipple hex until nipple hex shoulders against socket...

Page 4: ...BMK 15Ea 16Ea 17Ea PAGE TWO BP 194 BP 195 NOT TO SCALE NOT TO SCALE MOUNTING BRACKET TOP MOUNTING BRACKET BOTTOM 1 1 2 FITTING ADAPTER BP 201 ...

Page 5: ... 17Ea PARTS IDENTIFICATION SHEET BP 21 BP 22 BP 23 BP 185 BP 186 1 4 I D WASHER 1 4 NUT 1 4 X 1 BOLT 1 4 X 11 2 BOLT 1 4 FENDER WASHER 6 8 4 4 4 CUMMINS INTERNATIONAL NOT TO SCALE BP 178 1 O RING 35 8 I D NOT TO SCALE BP 191 BK 209 ALLEN HEAD PLUG FILTER MOUNT ASSEMBLY NOT TO SCALE 1 1 CUMMINS DURAMAX INTERNATIONAL FILTER ADAPTER BP 219 1 DURAMAX NOT TO SCALE BP 162 1 O RING NOT TO SCALE DURAMAX O...

Page 6: ... of the hose and restriction of flow Follow catalog specs on minimum bend radii RIGHT WRONG 6 Use proper bend radius cont Maximum bend radius is measured on the inside bend of the hose To determine minimum bend divide the total distance between ends B length by 2 For exam ple B 6 minimum bend radius 3 3 00 RADIUS 6 00 DIAMETER B 2 Avoid twisting and orient properly Do not twist hose during install...