background image

American Security Products Co.  

ESL15 Operating Instructions 

Released Aug. 9, 2018 

Revision A

 

Page 7 of 10 

 

o

 

To Enable 2 Subordinate User Opening in Dual Combo Mode:  

C - # - 31 - # - (Master Code) - # - 1 - # 

o

 

Disable 2 Subordinate User Opening in Dual Combo Mode:  

C - # - 31 - # - (Master Code) - # - 0 - # 

 

Armored Car TDL Bypass (Functions 40 & 41) 

o

 

To Enable Armored Car TDL Bypass: 

C - # - 40 - # - (Master Code) - # - 1 - # 
Note: Enabling Armored Car Bypass turns on (enables) User 9, which is the Armored Car User. The User 
9 combo must be set before this feature will function. See Section 4 for changing instructions. 

o

 

To Disable Armored Car TDL Bypass: 

C - # - 40 - # - (Master Code) - # - 0 - # 

o

 

To Enable Subordinate Authorizing User Armored Car TDL Bypass:  

C - # - 41 - # - (Master Code) - # - 1 - # 

o

 

To Disable Subordinate Authorizing User Armored Car TDL Bypass:  

C - # - 41 - # - (Master Code) - # - 0 - # 

 

Subordinate User Combo Change (Function 60) 

o

 

To Enable Subordinate User Combo Change:  

C - # - 60 - # - (Master Code) - # - 1 - # 

o

 

To Disable Subordinate User Combo Change:  

C - # - 60 - # - (Master Code) - # - 0 - # 

 
Reset All Functions (Function 99) 

o

 

To Reset All Functions: 

C - # - 99 - # - (Master Code) - # - 1 - # 

 

Mixed Modes 

 Any combination of modes can be active at the same time. Here are some situations that are possible and how they 

interact together. 

o

 

Dual Combo and Time Delay: Any one valid combo can start the Time Delay, but after the Delay Period, two 

different valid combo’s are necessary to cause lock opening. 

o

 

Armored Car Code, Dual Combo and Time Delay: Armored Car TDL Bypass only allows the bypassing of Time 
Delay. Two valid User codes are still necessary to open the lock even the when Armored Car Code is used to 

bypass Time Delay. 

o

 

Duress Alarm output will be caused any time the Duress code is entered by any User during opening or starting 

of Time Delay. Requires Expansion Module. 

o

 

Enabling Dual Combo Mode automatically adds a User 1, even if Multi-User Mode is disabled. Don’t forget to 
set a Code for User 1 or there will not be two codes to open the lock. 
 
 

Summary of Contents for ESL15

Page 1: ...ion 4 Press the key You should hear a short good combination tone 5 Key in your new 6 digit combination 6 Press the key You should hear a short good combination tone 7 Re key in the new 6 digit combination again 8 Press the key If the combination input matches the first pass you should hear a long good combination tone indicating your new combination has been recorded 9 Test your new combination s...

Page 2: ... pressed For example if you press C 1 2 3 4 5 7 4 5 2 7 6 the program recognizes only the C 1 2 3 4 5 6 input The last numeric key pressed continues to replace the one prior until the key is pressed to indicate completion This is a security feature that allows you to baffle any onlookers who may be trying to memorize your combination Replacing the Batteries Always use a fresh set of name brand Alk...

Page 3: ...feature allows the Time Delay to be used under normal access situations but provides a means to bypass time delay when cash handling methods require that an Armored Car courier can take deposits without waiting for the delayed access o This feature must be Enabled F40 o It still requires that a valid resident User be present to open the safe o The Armored Car Code User 9 can be keyed in first foll...

Page 4: ...ode is Enabled the Manager must be one of the two Users entering valid combinations Duress Alarm This feature allows a User to secretly signal that they are under Duress typically in the act of being forced to open the safe in a robbery situation o This feature must be Enabled F20 o This feature requires that one of the optional Expansion Modules ESL20EXP1 ESL20EXP2 or ESL20EXP3 is attached to pro...

Page 5: ...er Code Feature Setting with Function Codes The ESL15 s advanced features are controlled only by the Master User and are set using Function Codes A function can be turned on and off or set using the Function Code with the Master User code as authorization for changing or setting the function A Function Code is a 2 digit code that is associated to a particular setting Each Function Code has a defau...

Page 6: ...o set the Delay Period C 02 Master Code Delay Period 1 99 minutes o To set the Open Period C 03 Master Code Open Period 1 9 minutes Multiple User Settings Functions 10 11 12 13 o To Enable Multiple User Mode C 10 Master Code 1 o To Disable Multiple User Mode C 10 Master Code 0 o To Add or Enable a Subordinate User C 11 Master Code User Number 1 8 o To Disable a Subordinate User C 12 Master Code Us...

Page 7: ... Combo Change C 60 Master Code 1 o To Disable Subordinate User Combo Change C 60 Master Code 0 Reset All Functions Function 99 o To Reset All Functions C 99 Master Code 1 Mixed Modes Any combination of modes can be active at the same time Here are some situations that are possible and how they interact together o Dual Combo and Time Delay Any one valid combo can start the Time Delay but after the ...

Page 8: ... or 0 02 Time Delay Period 1 99 03 Open Period 1 9 10 Multiple User Mode 1 or 0 20 Duress Mode 1 or 0 30 Dual Combo Mode 1 or 0 31 Two Subord Combos Open 1 or 0 40 Armored Car TDL Bypass 1 or 0 41 Subord Auth of TDL Bypass 1 or 0 50 External Control Port 1 or 0 60 Subord User Combo Change 1 or 0 To track User assignments use this table User No Assigned To Date Assigned To Date Assigned To Date 0 1...

Page 9: ... of the lock inside the door The ESL15 relies on a solenoid to actuate this bolt That solenoid can only overcome so much resistance and if that resistance is too great the bolt does not retract To resolve this problem you must find a handle position that does not push the locking system up against the lock s bolt To find that place it helps to know which way the handle turns when you open the door...

Page 10: ...rt after Time Delay 6 Beeps The lock is in Penalty Lockout During this period the lock will not accept any input You must wait for the penalty lockout to expire The lock will Beep Flash once when this period ends Short Warble 3 high low tones for about 2 5 seconds Short Good Combination Tone indicates the input is accepted during a Combination Change Long Warble 13 high low tones for about 10 seco...

Reviews: