4  

Venus T5c Series

 

2. DIP Switch and RAID Mode cross reference 

User can configure any RAID mode as below by DIP switch and apply change by Change Mode button.   

   

Dip Switch 

RAID Mode 

1 2 3 

RAID 0 

ON 

ON 

ON 

RAID 10 

ON 

ON 

OFF 

JBOD (Large) 

ON 

OFF 

ON 

RAID 3 

ON 

OFF 

OFF 

Clone OFF 

ON 

ON 

RAID 5 

OFF 

ON 

OFF 

Reserved OFF OFF ON 

Normal (Single)

OFF 

OFF 

OFF 

PS: 

When DIP-SW is RAID10, 2 HDDs is RAID1 Mode and 4 HDDs is RAID10 Mode.

 

 

2.1 RAID 0 for High Performance 

 

RAID 0(or Stripe) is the segmentation of logically sequential data, such as a single file, so that segments 

can be assigned to multiple hard disks in a round-robin fashion and thus written concurrently. (If any hard 

disk becomes defective, information stored in this RAID0 will be invalid.)   

 

 
 
 
 
 

Summary of Contents for Venus T5c DS-2350C

Page 1: ...www american media com Page 1 Venus T5c Series Venus T5c series SATA RAID User Manual Model DS 2350C Model DS 2250C For 3 5 SATA For 2 5 SATA ...

Page 2: ... by DIP switch apply change mode switch LED indicators for System Ready HDD Error HDD Access Temperature fan 8x8cm Fan X 2 High Low speed selectable Reset switch or OTB switch for option Color BLACK Dim 215 L x156 W x211 H mm Patent products with advanced structure design Patent balance handle no skew in out problem and avoid the abrasion during connection Precisely connection on connector see Fig...

Page 3: ... D10 HDD Safety Lock D11 Power LED D12 Power Safety Lock The safety lock prevent it bouncing out while HDD is working D13 120W Switching Power Supply Rear View see Figure 5 Figure 5 E1 Cooling Fan 1 8x8cm E2 Fan Speed Control FAN RPM HIGH 3600rpm LOW 2800 rpm Options If you want the fan to run at a high speed switch to the right otherwise switch to the left E3 Cooling Fan 2 8x8cm E4 Reset Change M...

Page 4: ...N OFF OFF Clone OFF ON ON RAID 5 OFF ON OFF Reserved OFF OFF ON Normal Single OFF OFF OFF PS When DIP SW is RAID10 2 HDDs is RAID1 Mode and 4 HDDs is RAID10 Mode 2 1 RAID 0 for High Performance RAID 0 or Stripe is the segmentation of logically sequential data such as a single file so that segments can be assigned to multiple hard disks in a round robin fashion and thus written concurrently If any ...

Page 5: ... disk Failure in a hard disk Host controller still could read write data Users have to replace the defect hard disk T5 will enter on line auto rebuild mode automatically 2 3 Stripe Mirror RAID 10 for High Performance and High Security T5 could be configured to support Stripe and Mirror at the same time i e RAID 10 Take four hard drives RAID 10 as an example Hard drive 0 and hard drive 1 could act ...

Page 6: ...s at the same time 2 5 JBOD Concatenating This mode is also named Concatenating In this mode T5 will concatenate all of the hard drives into a single hard drive with larger capacity For example if three 500GB hard disks is connected to T5 in concatenating mode user will get a single hard disk with capacity of 1 500 GB 2 6 Parity Protection XOR engine in T5 generate parity block In RAID 3 mode Pari...

Page 7: ...g any defects Users have to replace the defective hard disk T5 then will enter on line auto rebuild mode automatically 2 7 Normal Mode Single Normal mode means all of the configured hard drives exist and T5 is not in rebuild condition User can see the original hard drives from the host which supports port multiplier technology If the host does not support port multiplier then you will find only on...