User Manual
– AS5x61/AS5x62 Programming
www.ams.com
Revision 1.0 / 10/31/12
page 5/14
12) Choose the desired quadrant mode
there are a possibility to programm up
to 4 quadrants @ 1 revolution.
There are some limits for this programming: 4 Quadrants: max. 90° for each Quadrant
3 Quadrants: max 120° for each Quadrant
2 Quadrants: max 180° for each Quadrant
1 Quadrant: full 360°
13) Choose the Breakpoint setting: a) Opt is the optimal Breakpoint, calculated by the DLL.
b) BP : set the BP in the BPW field
c) BP_T1: BP setting related to T1 position. Set value into
BPWT1D field
d) BP_T2: BP setting related to T2 position. Set value into
BPWT2D field
14) Additional Settings:
HystLevel: Only used with 1Q 0
– 360° to move the BP.
Direction: Set the right direction for the Application, CCW or CW.
15) Click
This will calculate the real values (scale factor, Breakpoint…). All this
information, in addition to voltages and angles, is needed to program the AS5x62.
Example:1 Quadrant