AMS AS5162 Programming Manual Download Page 3

 

User Manual 

– AS5x61/AS5x62 Programming 

 

www.ams.com              

Revision 1.0 / 10/31/12

 

page 2/14 

 

1. General Description 

This document describes the programming of the AS5x61 / AS5x62. 

The AS5x61 / AS5x62 is a contactless magnetic angle position sensor for accurate angular 

measurement over a full turn of 360°. A sub range can be programmed to achieve the best 

resolution for the application. It is a system-on-chip, combining integrated Hall elements, analog 

front end, digital signal processing and best in class automotive protection features in a single 

device.  

To measure the angle, only a simple two-pole magnet, rotating over the center of the chip, is 

required. The magnet may be placed above or below the  IC. 

The absolute angle measurement provides instant indication of the magnet’s angular position 

with a resolution of 0.022° = 16384 positions per revolution. According to this resolution the 

adjustment of the application specific mechanical positions are possible. The angular output data 

is available over a 12 bit ratiometric analog output.  

The ASx61 / AS5x62 operates at a supply voltage of 5V and the supply and output pins are 

protected against overvoltage up to +20V. In addition the supply pins are prote cted against 

reverse polarity up to 

–20V. 

 

The Demo software for programminf is available on the Webpage. www.ams.com  

 

 

 

 

 

 

Summary of Contents for AS5162

Page 1: ...www ams com Revision 1 0 2012 10 31 User Manual AS5x61 AS5x62 Programming AS5x61 AS5x62 Programming Example...

Page 2: ...5x62 Programming www ams com Revision 1 0 10 31 12 page 1 14 Table of Contents 1 General Description 2 2 Requirements Applies to all output types 3 3 AS5x62 Programming 3 4 AS5x61 Programming 8 Copyri...

Page 3: ...the angle only a simple two pole magnet rotating over the center of the chip is required The magnet may be placed above or below the IC The absolute angle measurement provides instant indication of t...

Page 4: ...cation over 1 PIN is necessary UART Interface board available 2 RS232 Connection on PC 3 Application Software Application Software www ams com 4 Labview Drivers for the Application Software 3 AS5x62 P...

Page 5: ...Cordic register initial position 6 Enter final angle T2 Two methods are possible except that this position is the final position of the magnet s rotation a Manually enter a final position value into...

Page 6: ...oose the Breakpoint setting a Opt is the optimal Breakpoint calculated by the DLL b BP set the BP in the BPW field c BP_T1 BP setting related to T1 position Set value into BPWT1D field d BP_T2 BP sett...

Page 7: ...AS5x62 Datasheet 22 To program an AS5262 DualDie Device redo point 20 and 21 for the Top Device 23 Two actions can happen at this point a You can confirm that the entered data operates as expected Go...

Page 8: ...ck 38 Click This will cause the AS5x62 to permanently enter into Output Mode when power is applied to it 39 Click 40 Click 41 Check if write read Chksum is green 42 To program an AS5262 DualDie Device...

Page 9: ...C GND and OUT for the communication If the ams UART Interface board is used please connect an external 5V Powersupply to the board 2 Start AS5x61 AS5x62 Evaluation Software Figure 1 AS5x6y GUI 3 Choos...

Page 10: ...9 Enter This is duty cycle at the final magnet position 10 Enter Clamping Level Low is the duty cycle at the lower guard band 11 Enter Clamping Level High is the voltage at the upper guard band 12 Ch...

Page 11: ...5 to step 15 on page 17 Click 18 Select the desired PWM Frequency 19 Set to activate the internal filter Default setting is no filter For further information please read AS5x62 Datasheet 20 Set to ch...

Page 12: ...xpected 29 If satisfied with the results go to Step 31 otherwise go to Step19 30 Reset the device You have to push the reset button on the UART Interface board by hand This will reset the programming...

Page 13: ...een 41 To program an AS5261 DualDie Device redo step 38 to step 41 for the Top Device 42 Click A message will appear 43 Click yes to accept CAUTION Once this is done the AS5x61 will permanently be pro...

Page 14: ...mal commercial applications Applications requiring extended temperature range unusual environmental requirements or high reliability applications such as military medical life support or lifesustainin...

Reviews: