5.1.1. Power Connection (Stand Alone Voltage Mode)
Refer to Figure 3. The sensor operates over the voltage range of 10 VDC to 28 VDC.
Connect the (+) side of the voltage source to connector J1-1 (V+). Connect the (-)
side of the voltage source to connector J1-3 (RTN). If the voltage output is used,
connect it to J1-2
(VOT).
FIGURE 3, STAND ALONE VOLTAGE MODE CONNECTION TO MONITOR SYSTEM
MC-4231-CO
V OUT
28 VDC
GND
MONITOR REMOTE
ANALOG INPUT
GND
+28VDC