620UK-B Operation and Maintenance Manual – Rev J – January 2020 

Page 3

   

 

 

 

 

 

 

 

 

 

 

 

 

13231 Rooster Springs Rd. 

Austin, TX 78737 

T:

 (512) 858-4045 

E:

 [email protected] 

amptec.com 

SECTION A: RECEIVING AND INITIAL INSPECTION 

 

A-1 Introduction to AMPTEC 620UK-B Bonding Milliohmmeter 

Originally designed at the request of Lockheed Martin’s engineering team, the AMPTEC 

620UK-B Bonding Milliohmmeter has become the standard in its industry, being used in 

maintenance wings across the globe. The 620UK-B meter provides extremely safe and 

reliable resistance testing on explosive or volatile devices at all times. Our various 

safety board approvals (found in section F on page 18) demonstrate our dedication to 

making quality products that are safe to use in a variety of atmospheres and 

environments. 

 

The AMPTEC 620UK-B Bonding Milliohmmeter is UL-913 approved as an intrinsically 

safe apparatus for use in Class 1, Division 1, Groups A, B, C, and D locations for 

ambient temperatures from -20° C to 50° C (T3 zones). The AMPTEC 620UK-B meter is 

also MIL. STD. 810 MTD. 511 approved for use in explosive and volatile atmospheres.  

 

Devices/processes that the 620UK-B meter can be used for include, but are not limited 

to:  

  Electrical chassis ground connections and continuity determination(s) on 

electrical subsystems used in general purpose aircraft, helicopters, fighter jets, 

UAVs, drones, missiles, etc. 

  Continuity determinations on fuses, electrical cable connections, heavy duty 

metal to metal connections 

  Bonding measurements for metal to metal connections 

 

Featuring an all metal case with a separate F.O.D. resistant battery compartment, the 

AMPTEC 620UK-B meter has been specifically designed to keep ease of use and 

reliability in mind. When it comes to safety, the 620UK-B meter has failsafe output 

circuitry pioneered by AMPTEC to ensure that test current levels do not exceed the 

specified failsafe current, even in worst-case component failure situations. 

 

We’re extremely proud of the engineering and quality that goes into each and every one 

of our products we’ve created over the past 20 years. We hope you enjoy working with 

our 620UK-B meter and encourage you to contact us if you have any questions or 

comments. Thank you for your business! 

 

A-2 Unpacking and Inspection 

Should the box you receive your product in be damaged upon its arrival, notify AMPTEC 

and the shipping carrier immediately. If your 620UK-B meter appears damaged, the 

carrier’s agent should authorize repairs before the unit is returned to our facility. 

 

If the unit fails to operate or meet performance specifications (listed in section B on 

page 5) notify the carrier’s agent and AMPTEC immediately. Retain the shipping 

container for the carrier’s inspection. 

 

Summary of Contents for 620UK-B

Page 1: ...13231 Rooster Springs Rd Austin TX 78737 T 512 858 4045 E info amptec com amptec com AMPTEC RESEARCH MODEL 620UK B OPERATION AND MAINTENANCE MANUAL...

Page 2: ...Feature Information p 9 D 3 620UK B Padded Carrying Case Photo and Information p 11 D 4 Detailed Use Description p 11 SECTION E MAINTENANCE REPAIR AND CALIBRATION E 1 General Maintenance Repair Calib...

Page 3: ...on electrical subsystems used in general purpose aircraft helicopters fighter jets UAVs drones missiles etc Continuity determinations on fuses electrical cable connections heavy duty metal to metal c...

Page 4: ...t has a low battery the display will say LO BAT To see instructions on battery replacement see section E 9 1 on page 17 4 Perform a visual test lead integrity check It is recommended that the user per...

Page 5: ...is 20 000 counts 4 digit liquid crystal display with a back light that indicates autolock See section D 2 7 on page 9 for additional information about the autolock feature Low Battery Indication Displ...

Page 6: ...d set with ground 630 305 4 Twin single banana jack lead set 630 401 4 Single point handheld Kelvin probes 630 405K 10 heavy duty spiked Kelvin probes 630 405S 10 heavy duty spear Kelvin probes 630 40...

Page 7: ...tart updating the LCD screen once an electrical connection has been made After approximately 3 seconds the meter will produce a beeping sound and the backlight will turn on to illuminate the LCD scree...

Page 8: ...wires then terminate in a variety of configurations depending upon the accessory The 620UK B keyed access connector also makes it virtually impossible during normal operation to incorrectly connect le...

Page 9: ...id crystal display and high quality the display itself should have a life lasting many years Should the display become damaged or stop operating properly it can be replaced at an AMPTEC facility The u...

Page 10: ...r to produce the final autolocked measurement which is the reading displayed while the backlight is on To assist the user the meter produces an audible beeping indicator along with the lit backlight o...

Page 11: ...including front and rear panels Item C 4 Digit LCD Display with LO BAT and OR shown as an example Item D AUTO MEASURE RESET BUTTON Press and hold to reset a measurement that has been locked Item E Pow...

Page 12: ...is on as the unit s autolock feature freezes the reading The backlit frozen measurement will stay frozen until you either press the AUTO MEASURE RESET button or press the test probes against a conduct...

Page 13: ...uct lines and is capable of fixing nearly any issue your instrument may have AMPTEC maintains one sole facility for both the manufacturing and repair of its products AMPTEC RESEARCH CORP 13231 Rooster...

Page 14: ...of test current On a 1 resistor the 620UK B 100mA output should get a 100mV drop 0 10V 0 10A For DVM scaling on the 2 range voltage drop is amplified using a x10 for range scaling hence a 10 mV drop b...

Page 15: ...eck for a reading of 0 000 3 Put the output leads across a 0 100 resistance standard 4 The display should read 100 00 m 10 counts depending on the resistor s accuracy If the above test proves untrue t...

Page 16: ...between readings for settling and an updated display of the measurement The meter will continue to sample and hold and then resample as long as it senses any continuity Finally connect the meter via t...

Page 17: ...e the front panel and screws E 9 Battery Compartment Design and Description The metal battery compartment is powder coated to make it chemically resistant to battery leakage and backed with a water ti...

Page 18: ...is certification was gained in 2013 and is maintained with quarterly inspections by an independent party AMPTEC also follows UL 913 s quality standards plant wide including the adoption of a quality m...

Page 19: ..._________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________...

Reviews: