Copyright 2021 Ampt LLC.
All rights reserved.
34
String Optimizer V1500-20 Platform
Installation Manual: 57070012-1 J
16 A models (V1200 - V1325)
Vxxxx-20-16 Models
V1200
V1225
V1250
V1275
V1300
V1325
Model Number
31570021-1200
31570021-1225
31570021-1250
31570021-1275
31570021-1300
31570021-1325
Electrical
Input
Maximum voltage per input ¹
V
1500
1500
1500
1500
1500
1500
Maximum current (Imp) per input ²
A
12.3
12.3
12.3
12.3
12.3
12.3
Maximum short-circuit
current (Isc) per input
A
13.3
13.3
13.3
13.3
13.3
13.3
MPP tracking voltage range
V
400 - 1135
400 - 1160
400 - 1185
400 - 1210
400 - 1235
400 - 1260
Startup voltage per input
V
510
510
510
510
510
510
Number of inputs
2
2
2
2
2
2
Output
Output voltage range
V
0 - 1200
0 - 1225
0 - 1250
0 - 1275
0 - 1300
0 - 1325
Output voltage at full power
V
1135
1160
1185
1210
1235
1260
Output voltage at zero power
V
1200
1225
1250
1275
1300
1325
Maximum output current
A
16
16
16
16
16
16
Maximum continuous output power
kWdc
17.7
18.1
18.5
18.9
19.3
19.7
Efficiency (max / CEC / Euro)
%
99.6 / 99.5 / 99.4
Mechanical
Input & output connector
Amphenol H4
Dimensions
13.31” x 8.66” x 3.94”
(338 mm x 220 mm x 100 mm)
Weight
11.6 lbs. (5.3 kg)
Ambient temperature
operating range
-40 °F to +122 °F
(-40 °C to +50 °C)
Cooling
Convection
Environmental
Environmental category
Outdoor
Pollution degree
2
Maximum operating altitude³
9843 ft (3000 m)
Overvoltage category
OVII
Ingress protection
IP66 / 4X
General
Compliance
ETL to UL 1741;
IEC 61000-6-1, 61000-6-3, 62109; CE;
Giteki 2-1-19; FCC Part 15, class A
1. Voc at coldest design temp. Follow Ampt’s design guidelines to determine the number of modules per input and max. system v
oltage.
2. Maximum Imp of modules on the input at standard test condition (STC) - irradiation level of 1000 W/m² at 25°C.
3. Optimizer derates above this altitude.