10
11
Electrical:
Sensitivity:
typical as listed on the table below
LOW Voltage
(Hold the TIC 300 PRO when making the detection range
measurement for LOW voltage range. The TIC 410A
Hot Stick must be used when making detection range
measurement for High voltage range)
Voltage
(Phase to neutral with
890K Ohm load)
Detection Range
(From the TIP of probe to
the target line)
Average
30V
1.5”
75V
6.5”
100V
8.5”
120V
10”
220V
1’1”
500V
1’7”
1000V
2’10””
HIGH Voltage
Voltage
(Open Phase with no load)
Detection Range
(From the TIP of probe to
the target line)
Average
1.5 kV
0.5”
2.0 kV
1”
4.0 kV
2”
10.0 kV
8”
15.0 kV
1’2”
20.0 kV
1’8”
25.0 kV
2’2”