14
2. Repeat step 1 with the other end of the lamp.
Figure 10: Plug
the lamp into the
pin test slots
LED indicator ON
Solid continuous beep
Figure 11: Pin test indications
DETAILED SPECIFICATIONS
Test voltage
(with new battery)
Approximately 3 kV / 280 kHz
Field strength
Approximately 100 μV/m at 260 - 300 kHz
Maximum antenna
length
121.92cm (48”)
Filament test
T2, T4, T5, T8, T9, T10, T12
Non-contact voltage
detection
AC 90 V to AC 600 V, 50/60 Hz
CAT III 300 V, CAT II 600 V
Non-contact voltage
sensitivity (with probe)
LED illuminates and beeps at approximately 3 mm
(0.12 in) distance from a wire carrying 120 Vac
LED illuminates and beeps at approximately 5 mm
(0.2 in) distance from a wire carrying 230 Vac
Drop proof
1 meter
Operating time
One second ON, one second OFF for maximum
five cycles and wait for 1 minute before making
another measurement
Operating temperature
-10
O
C to +50
O
C (14
O
F to 122
O
F) ≤85% RH
Storage temperature
-10
O
C to +50
O
C (14
O
F to 122
O
F) ≤85% RH
Operating altitude
Up to 2000 meters