background image

5

SymboLS

battery

Refer to the manual

double insulated

dangerous Voltage

direct Current

earth ground

Alternating Current

Audible tone

Conforms to relevant Australian 
standards.

Complies with eU directives

do not dispose of this product as 
unsorted municipal waste.

Underwriters laboratories.

Application around and removal 
from hazardous live conductors 
is permitted

INTRodUCTIoN

AMpRobe is dedicated to designing, manufacturing and marketing high quality, reliable 
instruments for the skilled professional. AMpRobe has a history of providing safe, reliable 
equipment to trace energized wires, circuit breakers, tracing deenergized wires, and locating 
opens. The AT-1000 Advanced Tracing System combines these features in one versatile tool and is 
effective in solving most tracing problems.
The AT-1000 is a troubleshooting tool. An experienced troubleshooter will understand how 
the system to be traced works under normal conditions, and be familiar with the types of 
malfunctions that can exists. A thorough understanding of “ohms law” is helpful. it is a 
good idea to test the circuit for parameters such as Volts, ohms, and Current to determine 
whether the circuit is “shorted”, “semi-shorted”, or “open”, before attempting to trace. The 
characteristics of these malfunctions will designate which components, and tracing method, will 
be most effective in locating these malfunctions.
A thorough understanding of the operation and function of each of the AT-1000 components is 
essential. overall, this knowledge could mean the difference between spending several minutes 
or several hours on a job. pay special attention to the “Safety precautions and Warnings”. 
experiment under known conditions. You will gain the confidence to use it on a daily basis and 
solve problems which were previously unsolvable.

SAfETy PRECAUTIoNS ANd WARNINgS

Read this manual in its entirety before proceeding with any testing.

1. 

Summary of Contents for AT-1000

Page 1: ...AT 1000 Advanced Wire Tracer Users Manual ...

Page 2: ...English AT 1000 Advanced Wire Tracer Users Manual AT1000_Rev001 2008 Amprobe Test Tools All rights reserved ...

Page 3: ...nd proof of purchase Additionally please include a brief description of the problem or the service requested and include the test leads with the meter Non warranty repair or replacement charges should be remitted in the form of a check a money order credit card with expiration date or a purchase order made payable to Amprobe Test Tools In Warranty Repairs and Replacement All Countries Please read ...

Page 4: ...3 R1000 Receiver X1000 Transmitter ...

Page 5: ...afety Precautions and Warnings 5 Unpacking and inspection 6 Component Description 6 R1000 Receiver 6 X1000 Transmitter 6 Replacing Batteries R1000 and X1000 7 Operation 7 Tracing Energized Wires 7 Locating Opens 8 Locating Shorts 8 Fuse Replacement 8 Specifications 9 ...

Page 6: ...roubleshooter will understand how the system to be traced works under normal conditions and be familiar with the types of malfunctions that can exists A thorough understanding of Ohms Law is helpful It is a good idea to test the circuit for parameters such as Volts Ohms and Current to determine whether the circuit is shorted semi shorted or open before attempting to trace The characteristics of th...

Page 7: ...ng and inspection AT 1000 US version AT 1000E Europe version 1 x R1000 Receiver 1 x R1000 Receiver 1 x X1000 Transmitter 1 x X1000 Transmitter 1 x C2901 Cordset 2 x Test probes in set EU 200 1 x C2902 Cordset 2 x Crocodile clips in set EU 200 1 x AD 1 Adapter 2 x Test leads in set EU 200 1x Instruction Manual 1 x Instruction Manual 1x Soft Carrying case 1 x Hard carrying case 2 x 9V Battery 2 x 9V...

Page 8: ...ation that can be detected by the R1000 in the CURRENT mode along the circuit path The signal will flow to the lowest impedance in the circuit Usually the signal is more evident and detected on the conductors going back to the source transformer To increase the signal current travelling to the source transformer disconnect any know loads on that circuit When connected to an open circuit the X1000 ...

Page 9: ...oximity of each other the signal strength is attenuated see Fig 5 This can make tracing conductors more difficult if not impossible In most cases you can solve this problem by using the C2902 cord set and connecting one output terminal to a different signal return path Use something other than the return neutral running adjacent to the conductor you are trying to trace like a water pipe or a groun...

Page 10: ...another angle if possible Pinpoint the location of the open where the signal drops off by reducing the sensitivity while decreasing the distance between the R1000 and the conductor If possible repeat the process starting from the other end of the wire to verify the location 6 of the open Locating Shorts Using the C2902 Cord Set connect the X1000 Transmitter to the shorted conductor and a 1 separat...

Page 11: ...10 Fig 1 Battery Replacement Fig 2a C2901 Cordset Fig 2b C2902 Cordset Fig 3 EU 200 Cordset ...

Page 12: ...11 Fig 4 Locating Breakers Fig 5 Signal Attenuation ...

Page 13: ...12 Fig 7 Tracing Wires Fig 6 Tracing Conductors ...

Page 14: ...13 Fig 8 Tracing Opens Fig 9 Locating Shorts ...

Page 15: ...14 Fig 10 Fuse Replacement Fig 10a Back View Fig 10b X1000 with Front Cover Removed ...

Page 16: ...Please Recycle Visit www Amprobe com for Catalog Application notes Product specifications User manuals ...

Page 17: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information AMPROBE AT 1000 ...

Reviews: