c
CAPACITANCE MEASUREMENTS
In many instances a motor can not be started due to a failed start/run capacitor. To
test the capacitor:
: Discharge the capacitor before testing.
1 ) Set the rotary switch to "
µ
F" position.
2) Insert the black test lead to "COM" terminal and red test lead to "V -
Ω
-
µ
F"
terminal.
3) Remove at least one leg of the capacitor from circuit board or device.
4) Touch the test leads across the capacitor and read the display.
Note: If you are measuring a polarity sensitive electrolytic capacitor, touch the red
test lead to the positive end of the capacitor, and the black test lead to the negative
end of the capacitor.
43
Summary of Contents for ACDC-620T
Page 12: ...11 Figure 2 LCD Display ...
Page 31: ...Figure 17 Measuring AC Current CORRECT INCORRECT 30 ...
Page 33: ...Figure 18 Measuring AC Curreft 32 ...
Page 35: ...Figure 19 Measuring AC Motor Curent 34 ...
Page 37: ...Figure 20 Measuring Voltage 36 ...
Page 39: ...Figura 21 Measuring Resistance and Continuity FUSE CARTRIDGE 38 ...
Page 41: ...Figure 22 Surface Temperature Measurement 40 Press Shift ...
Page 45: ...Figure 24 CAPACITANCEMEASUREMENTS 44 Negro Rojo ...
Page 63: ...62 Figure 26 step 1 of Battery replacement Pull up slightly ...
Page 64: ...63 Figure 27 Step 2 of Battery Replacement Pull and move to right ...