On-Board Serial Ports
NOTE
Serial Ports 1 and 2 can not share the same IRQs, and the IRQs used
for Serial Ports 1 and 2 can not be used for Serial Ports 3 and 4 and
vice versa.
♦
Serial 1 – [Disabled], [
3F8h
], [2F8h], [3E8h], [2E8h], [260h], [2F0h], [3E0h], [2E0h],
[200h], or [220h]
This field specifies the base address used for Serial Port 1.
•
IRQ – [none], [1], [3], [
4
], [5], [6], [7], [9], [10], [11], [12], [14], or [15]
This field specifies the IRQ used for Serial Port 1. If this field is set to [none], then no
IRQ is assigned, making it available for other devices.
♦
Serial 2 – [Disabled], [3F8h], [
2F8h
], [3E8h], [2E8h], [260h], [2F0h], [3E0h], [2E0h],
[200h], or [220h]
This field specifies the base address used for Serial Port 2.
•
IRQ – [none], [1], [
3
], [4], [5], [6], [7], [9], [10], [11], [12], [14], or [15]
This field specifies the IRQ used for Serial Port 2. If this field is set to [none], then no
IRQ is assigned, making it available for other devices.
♦
Serial 3 – [Disabled], [3F8h], [2F8h], [
3E8h
], [2E8h], [260h], [2F0h], [3E0h], [2E0h],
[200h], or [220h]
This field specifies the base address used for Serial Port 3. If this field is set to [Disabled],
then the port is not used, then no IRQ is assigned, making it available for other devices.
•
IRQ – [3], [4], [5], [7], [9], [10], or [
11
]
This field specifies the IRQ used for Serial Port 3.
•
Mode – [
RS-232
] or [RS-485]
This field specifies the signal mode, RS232, or RS485, used for Serial Port 3. If [RS-485]
mode is selected, the RTS signal should be used to control the direction for this port
(transmit or receive).
♦
Serial 4 – [Disabled], [3F8h], [2F8h], [3E8h], [
2E8h
], [260h], [2F0h], [3E0h], [2E0h],
[200h], or [220h]
This field specifies the base address used for Serial Port 4. If this field is set to [Disabled],
then the port is not used, then no IRQ is assigned, making it available for other devices.
•
IRQ – [3], [4], [5], [7], [9], [
10
], or [11]
This field specifies the IRQ used for Serial Port 4.
•
Mode – [
RS-232
] or [RS-485]
This field specifies the signal mode, RS232, or RS485, used for Serial Port 4. If [RS-485]
mode is selected, the RTS signal should be used to control the direction for this port
(transmit or receive).
•
On-Board LPT Port
♦
LPT 1 – [Disabled], [
378h
], [278h], [3BCh], [370h], or [270h]
This field specifies the base address used for the Parallel Port (LPT 1).
•
IRQ – [none], [1], [3], [4], [5], [6], [
7
], [9], [10], [11], [12], [14], or [15]
This field specifies the IRQ used for the Parallel Port (LPT 1). If this field is set to
[none], then no IRQ is assigned, making it available for other devices.
Summary of Contents for ReadyBoard 700
Page 1: ...ReadyBoard 700 Single Board Computer Reference Manual P N 5001722A Revision C ...
Page 6: ...Contents vi Reference Manual ReadyBoard 700 ...
Page 10: ...Chapter 1 About This Manual 4 Reference Manual ReadyBoard 700 ...
Page 60: ...Chapter 3 Hardware 54 Reference Manual ReadyBoard 700 ...
Page 78: ...Chapter 4 BIOS Setup 72 Reference Manual ReadyBoard 700 ...
Page 80: ...Appendix A Technical Support 74 Reference Manual ReadyBoard 700 ...
Page 88: ...Index 82 Reference Manual ReadyBoard 700 ...
Page 89: ......
Page 90: ......