background image

 
   

 

 

User Manual of 

 

C15-WCDMA Repeaters 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amplitec Corporation 

 

Summary of Contents for C15-WCDMA

Page 1: ...User Manual of C15 WCDMA Repeaters Amplitec Corporation...

Page 2: ...ectrical Specification 4 3 5 Mechanical Specification 4 3 6 Appearance Diagram 5 3 7 Ports 5 Chapter 4 Installation 6 4 1 Installation requirements 6 4 2 Installation 6 4 3 Connection 7 Chapter 5 Repe...

Page 3: ...power in advance Only the professional can operate electrified 3 Do not dismantle machine maintain or displace accessories by yourself because in this way the equipment may be damaged or even get an...

Page 4: ...eas Single band selective repeaters mainly applied in covering small blind and weak zones C15 WCDMA repeater is a good choice for weak signal area of WCDMA system such as VIP rooms offices houses rest...

Page 5: ...V 2A 3 2 Features Compact design and light weight cost effectiveness LED indication for operation status Selective band function to work on WCDMA support Low power consumption Low interference Applica...

Page 6: ...ALC 20 dB In band ripple 8dB P P Noise Figure Uplink 6 0 Group Delay 1 5 s Inter modulation Spurious Emission 36dBm 9KHz 1GHz 30dBm 1GHz 12 75GHz Power Supply Adaptor Input AC 165 265V RF Connector N...

Page 7: ...User Manual of C15 WCDMA Repeaters 5 3 6 Appearance Diagram 3 7 Ports...

Page 8: ...them should be keep as far away as possible it s better that there is a wall as the obstruct between them Position selection Install in the place that is not easy to be reached by irrelevant people In...

Page 9: ...Installation step ten component 1 onto the wall 2 Put the component 2 into component 1 4 3 Connection Connection of RF cable Input Port put the antenna outdoor and try to put on the place where there...

Page 10: ...us Definition of ALARM green Meaning working in linearity attention Input signals may be not enough red Meaning overloading or self oscillation strong input signals Attention cut the connection of equ...

Page 11: ...3 Curve of output power input signal and attenuation value POutput Power output power Pinput Power input power VATT attenuation vale Pinput Power VATT input power attenuation value Pmax output power...

Page 12: ...opened 6 2 Emergency dealing Switch off is recommended during following situations The power supply is not normal Liquid flows into the equipment Working conditions is not normal overheating abnormal...

Reviews: