background image

Magic 485F Adapter

Page  

9

3 TECHNICAL SPECIFICATION

The technical characteristics of the Magic 485F Adapter are in accordance with the following
electrical and physical specifications.

Except where otherwise noted, all specifications are typical at 25º C

Electrical Specification

Supply Voltage

+5.0 VDC to +12.0 VDC
from external supply via terminal strip

Supply Current

50 mA plus current drawn by output loads
100 mA fully loaded

RS232  'High' signal input

+2.4 to +30 V

RS232  'Low' signal input

–30 to +0.8 V

RS232 Input Resistance

5 k

RS232  'High' signal output

+9 V

RS232  'Low' signal output

–9 V

RS232 Output Resistance

300 

RS422/485 Input sensitivity 

0.2 V

RS422/485 Input Hysteresis

70 mV

RS422/485 Output drive

1.5 V minimum, fully loaded

RS422/485 Output load

27 

 minimum

RS422/485 Receiver I/P Termination

120 

 resistor across differential input terminals.

Can be disconnected by switching SW1-4

Data Rate

120 kBd max

RS232 Connector

25 way DB-25 female connector with screw-locks

RS422/485 Connector

8 way pluggable screw terminal assembly

Physical/Environmental Specification

Module with connector

Packed

Size

67 x 53 x 20 mm

215 x180 x 80 mm

Weight

60 gm

250 gm

Temperature Range

Operating

Storage

0° C to +60° C

-20 to +70° C

Summary of Contents for Magic 485F25

Page 1: ...oduct in a proper and efficient manner The information contained has been reviewed and is believed to be accurate and reliable however Amplicon Liveline Limited accepts no responsibility for any problems caused by errors or omissions Specifications and instructions are subject to change without notice Magic 485F Instruction Manual Part Nº 859 933 74 Issue A3 Amplicon Liveline Limited Prepared by J...

Page 2: ...clare that the product s described in this Instruction Manual perform in conformity with the following standards or standardisation documents Electro Magnetic Compatibility EMC EN55022 1995 Emission Standard BS EN50082 1 1992 Generic Immunity Standard EMC Directive 89 336 EMC Jim Hicks I Eng FIEIE Managing Director Amplicon Liveline Limited ...

Page 3: ...signals are connected through a pluggable 8 way screw terminal assembly at the free end of the Adapter 1 2 The Products Described in this Manual The 485F range of boards share some common circuitry and features and are referred to in this manual either generically or individually 485F Refers to both boards 485F25 Refers to the 25 way D type version only 485F9 Refers to the 9 way D type version onl...

Page 4: ...the information in this manual to ensure that the product is being correctly applied If an application problem persists please request Technical Support on one of the following numbers Telephone UK 01273 608 331 International 44 1273 608 331 Fax UK 01273 570 215 International 44 1273 570 215 E mail support amplicon co uk Internet www amplicon co uk 1 5 Repairs If the Magic 485F Adapter requires re...

Page 5: ...number on the outside of the packaging to ensure that the package is accepted by the Goods Inwards Department Address repairs to Customer Services Department AMPLICON LIVELINE LIMITED Centenary Industrial Estate Brighton East Sussex BN2 4AW England ...

Page 6: ...rough a pluggable 8 way screw terminal connector assembly at the free end RS422 485 Connections on 8 way Pluggable Terminal Strip The DC power input RS485 transmission turnaround external control signal and RS422 485 data signal connections are made via an eight way screw terminal connector The supplied connector can be unplugged from the Adapter for ease of making the cables without removing the ...

Page 7: ...or convenience the plastic case is supplied in two parts and should only be clipped together when any configuration changes have been made Operational tests can be performed before the case is fitted FIGURE 2 1 485F25 BOARD LAYOUT AND JUMPER POSITIONS FIGURE 2 2 485F9 BOARD LAYOUT AND LINK POSITIONS SK2 PL1 J2 C2 U1 C3 U4 U5 C6 R5 C2 U3 C1 R6 J3 C7 R4 R3 R2 C5 C4 R1 D1 J1 ...

Page 8: ...er Transmission Line Termination For proper operation of the RS422 485 bus in full or half duplex multi drop or point to point communication it is recommended that termination be applied to the receiver end of the data lines The simplest form of termination is line to line with typically a 120 Ω resistor across the differential input In a multi drop system the terminator resistor is only required ...

Page 9: ...ed OFF OFF OFF X RS485 transmitter turnaround time 4 us ON OFF OFF X RS485 transmitter turnaround time 8 us OFF ON OFF X RS485 transmitter turnaround time 16 us ON ON OFF X RS485 transmitter turnaround time 32 us OFF OFF ON X RS485 transmitter turnaround time 64 us ON OFF ON X RS485 transmitter turnaround time 128 us OFF ON ON X RS485 transmitter turnaround time 256 us ON ON ON X RS485 transmitter...

Page 10: ...s supply voltage must be 230 VAC 10 50 Hz The DC output is by a two wire cable approximately 2 m in length This cable is terminated in a moulded connector which must be cut off and discarded The two wires can then be parted and stripped back about 6 mm The black wire is negative and goes to terminal 8 GND of the Magic 485F Adapter and the black wire with a white stripe is positive and goes to term...

Page 11: ...ut Resistance 5 kΩ RS232 High signal output 9 V RS232 Low signal output 9 V RS232 Output Resistance 300 Ω RS422 485 Input sensitivity 0 2 V RS422 485 Input Hysteresis 70 mV RS422 485 Output drive 1 5 V minimum fully loaded RS422 485 Output load 27 Ω minimum RS422 485 Receiver I P Termination 120 Ω resistor across differential input terminals Can be disconnected by switching SW1 4 Data Rate 120 kBd...

Reviews: