16
MAINTENANCE
WARNING: DO NOT leave the housing exposed to direct sunshine, as extreme heat condition can be detrimental
to certain of its components.
1.
Keep housing and o-rings away from direct sunlight. Always store unit when possible away from direct sunlight as this
can dry out and crack o-rings in the housing. Ultraviolet rays can damage plastics, paint and o-rings.
2.
Always rinse or soak closed housing in fresh water for 10 to 15 minutes after every use. Reach into freshwater and
operate all controls to clear salt water. Do not use solvents to clean unit. If preferred, use mild detergent and clean fresh
water.
3.
Fasteners that are removable should occasionally have the threads lubricated with silicon grease.
4.
Rinse clean and remove water spots from external filters and lens surface after every dive or water spots may build up
and become impossible to remove. Dry gently with a soft, lint-free cloth.
5.
Inspect housing's rear door main o-ring seals (double seals) before every dive. Make sure that there are no cracks or
misalignment in the o-ring channel and that no debris is caught on the o-rings.
6.
During storage or transit, leave rear door ajar on unit to prevent damage due to extreme high pressure.
SERVICING O-RINGS
1.
O-rings and sealing surface should be lightly lubricated with silicon lubricant on a regular basis. This is not necessary
after every dive; every tenth dive during regular heavy use is sufficient. This should always be done before storing the
housing and before a first dive after taking the housing out of storage.
2.
It is important never to use a sharp instrument when removing an o-ring as this may cause damage to the o-ring or the
o-ring groove. A hairpin or a credit card works well.
3.
The removed o-ring should be examined for damage. Check to make sure that the o-ring is free from nicks and cuts
and that it retains its original round profile. O-rings that appear to be damaged should be discarded immediately and
replaced with new o-rings.
4.
Rinse the o-ring with freshwater and dry it with a clean lint free cloth.
5.
Clean the o-ring grooves (where the o-rings sit) with a Q-tip. Be sure to remove any lint the Q-tip may leave behind.
Inspect the groove for damage.
6.
Wipe the part of the housing that the o-ring seals against with a clean lint free cloth.
7.
Re-grease the o-rings with a thin layer of silicon grease until it appears to be smooth and shiny. Do not over grease it -
use just enough grease so that the o-ring will pull smoothly through your fingers. Excessive amounts will only attract dirt to
the o-ring.
8.
Replace o-rings in their proper position on the lens assembly and on the main door seal.