步骤5: 调试好免换模压接机BZW-6C,将端子压接在线材上(详细规格参照手册最后的附录) 
Step5: Set up the mould-free crimp machine BZW-6C, Then crimp the terminal on the wire. 
(please refer to the appendix at the end of this manual for more crimping information)    

03/05 

步骤7:插入R4 holder到②绝缘筒上, 转动使其触底 
Step7:Bring ② insulation sleeve through R4 holder and rotate ② insulation sleeve until it arrives at a stop  
             position 

步骤8:将半成品如下图示插入①屏蔽壳组件, 注意方向正确,防止损伤HVIL端子,插到底后翻转接头,打开摇杆,

固定外壳与电缆, 以10~12N∙m拧紧尾盖,依次完成此端线束组装。 
Step8:Insert the semi-finished product into ① Shielding shell assembly as shown below, pay attention to the 

correct direction to prevent damage to the HVIL terminal, after insert it into the end, turn over the connector, open 

the press latch, fix the housing and cable, tighten the end cap with 10~12N∙m, and complete assembly of the 

wire harness at this end in turn.  

    横截面 

Cross section

 

H

  

W

  

PL182X-301-70-G95 二芯 70mm2 直头插头组装规范  PL182X-301-70-G95  2 POS 70mm2 180D Straight Plug Assembly Manual    

Manual P/N

8P1174 _ Rev.01  20221115 

⑴ 

建议使用附录中的线材,如果要使用其它的线材,请联系当地销售,让他们提供延伸的产品。 

    Cables written in the appendix are highly recommended for crimping, please contact our local sales for help if 

you want to use other cables out of this table. 

⑵ 

压接高度和拉拔力需要配合压接截面的金相分析,客户才能判断压接质量合格,芯线压缩比要求为 80~90%。 

Customers need to reconfirm cross section on crimping area and pull out force test to confirm the quality of crimp 

process,Terminal crimping must  meet the conduct compression ratio requirements: 80~90% 

 横截面仅供参考,客户负责采购压接工具或刀模。 

The cross section is for reference only. The customer is responsible for purchasing crimping tool or dies. 

步骤6:组装④定位套到R4 holder脖颈处的沟槽。 
Step6:Take a ④ positioning sleeve and buckle up together to the neck groove of R4 holder. 

④定位套 

positioning 

sleeve 

确保R4尾部可见 

Make sure R4 end visible 

②绝缘筒

insulation 

sleeve  

Summary of Contents for PL182X-301-70-G95

Page 1: ...gec com PL182X 301 70 G95 70mm2 PL182X 301 70 G95 2 POS 70mm2 180D Straight Plug Assembly Manual Manual P N 8P1174 Rev 01 20221115 X Y Key X Y 0 1 HVIL 0 NO 1 WITH Cable Size mm2 70 FHLR2GCB2G PL182 X...

Page 2: ...POS 70mm2 180D Straight Plug Assembly Manual Part 1 Package contents Shielding shell assembly 1 Insulation sleeve with HVIL contact spring 2 300 insulation sleeve only in 300 series R4 R4 terminal As...

Page 3: ...We need to prepare two sets of products 4 1PCS Step4 Scatter and fold the braiding evenly Take 1PCS of inner metal gasket onto the braiding then fold the braiding onto it Trim it flat as shown in the...

Page 4: ...plete assembly of the wire harness at this end in turn Cross section H W PL182X 301 70 G95 70mm2 PL182X 301 70 G95 2 POS 70mm2 180D Straight Plug Assembly Manual Manual P N 8P1174 _ Rev 01 20221115 Ca...

Page 5: ...Current Cable power to shell 5000 VDC 10S 5mA Cable power to HVIL 5000 VDC 10S 5mA HVIL to shell 500 VDC 1S 5mA 04 05 9 3 PowerLok 1000VDC 9 3 Test note caution Recommended electrical tests and their...