4.6

Put the connector parts into the plug as shown below .

 

 

 
 
 
 
 
 
 
 
 
 

5. TEST INSTRUCTIONS  

5.1

100%High-voltage

insulation test

 

AC3000V, 10S, Leakage current

5mA. DC 500V, 10S, Insulation resistance

100M

  

 

5.2

100% Continuity test.

    

 
5.3、

100% IPX7 Water proof test.

   

 

6. ASSEMBLY INSTRUCTIONS 

(Receptacle)

 

6.1

0.5mm² signal wire strip insulation  as shown below.

 

 
 
 
 
 
 
 
 
 
 
 
6.2

Crimping signal terminal, after crimping, the retention force 

75N,  

 
 
 
 
 
 
 

Assembly direction 

The latch 
stop should 
be visible

 

 
Final Assembly 

6.0±0.5mm

2mm(ref)

Insulatio

Cable

Summary of Contents for HVSL1200

Page 1: ...00 Connector Page 1 of 7 Subject HVSL1200 Guidelines for Connector Assembly Eff Date 2018 01 24 F 0011 A Revision History Date Rev Updated Content Originator Remark 2018 01 24 A First release Prepared...

Page 2: ...the HVSL1200 connector 2 ASSEMBLY INSTRUCTIONS Straight Plug 2 1 Choose required shielding cable as follow 2 2 End plastic cap seal ring onto cable as shown 2 3 Strip jacket braiding wire insulation...

Page 3: ...he shielding wire use the fixture crimping after crimping crimping shape dimensions as shown FYI retention force as below 2 5 Crimping the contacts according to the as below standard Cable spec Crimp...

Page 4: ...NS 3 1 100 High voltage insulation test AC3000V 10S Leakage current 5mA DC 500V 10S Insulation resistance 100M 3 2 100 Continuity test 3 3 100 IPX7 Water proof test 4 ASSEMBLY INSTRUCTIONS R A Plug 4...

Page 5: ...to the shielding wire use the fixture crimping after crimping crimping shape dimensions as shown FYI retention force as below 4 5 Crimping the contacts according to the as below standard Cable spec L1...

Page 6: ...UCTIONS 5 1 100 High voltage insulation test AC3000V 10S Leakage current 5mA DC 500V 10S Insulation resistance 100M 5 2 100 Continuity test 5 3 100 IPX7 Water proof test 6 ASSEMBLY INSTRUCTIONS Recept...

Page 7: ...sembly Eff Date 2018 01 24 F 0011 A 6 3 Put the signal terminal into the receptacle as shown below 7 TEST INSTRUCTIONS 7 1 100 High voltage insulation test power pins and power pins power pins and shi...

Reviews: