Doc. No.: APCD-TD-395
Rev.: A
Amphenol
PCD Shenzhen
HVSL1200 Connector
Page:
3
of
7
Subject: HVSL1200 – Guidelines for Connector Assembly
Eff. Date: 2018-01-24
F-0011-A
2.4
、
Shielding wire backward turn
,
put the shielding ferrule onto the shielding wire
,
use the
fixture crimping, after crimping, crimping shape /dimensions as shown(FYI)
.
retention force as below.
2.5、
Crimping the contacts according to the as below standard.
Cable spec
Crimp dimensions A (mm) Retention force(N)
70mm² 20.0±0.1(FYI)
≥
100N
95mm² 23.0±0.1(FYI)
≥
100N
Cable spec
Crimp dimensions B(mm) Retention force(N)
70mm² 12.8±0.1(FYI)
≥
3400N
95mm² 13.5±0.1(FYI)
≥
4200N
B
Shielding wire
backward turn
A
33.6±0.5mm