background image

Connections

Connection of 

male XLR for microphone

input

balanced

+ (Signal hot)

- (Signal cold)

1

2

3

Screen

TIP

SOURCE

TO  ILD122

LINE INPUT

SLEEVE

RING

Connection of 3-pole Plug

with balanced signals.

Use Twin-screened cable.

+ (Signal hot)

- (Signal cold)

LINE
INPUT

MIC
INPUT

SLAVE
I/O

LOOP 
CONNECTOR

+ (Signal)

TIP

SOURCE

TO  ILD122

SLEEVE

RING

LINE INPUT

Connection of 3-pole plug.

Use Twin-screened cable.

Must be 3m or less.

Unbalanced 

Balanced 

TIP

RECORDING DEVICE

TO  ILD122

SLAVE I/O

SLEEVE

RING

Connection of 3-pole Plug

to use Slave I/O socket

for recording output.

+ (Signal)

1

2

Twisted feeder cable to loop

Undo the screw to remove the 
cover. Strip 5mm of insulation from 
the feeder wires and insert into loop 
connector. Tighten the retaining 
screws and replace the cover.

INSTALLATION

Location: 

The unit may be free standing or 19” rack mountable using a rackmount 
tray (RM1-U) and blanking plate in a ½ and ¼ widths as optional extras. 
Remove four rubber feet.

The location must provide satisfactory ventilation for the equipment. 

 If the unit is installed in an enclosed environment, sufficient air flow 

into the enclosure must be provided through vents, fans or other means. 

Tools & Equipment:

Small hand tools including a wire stripper and a small flat bladed 
screwdriver.

An ILR3 loop receiver or a magnetic field strength meter is vital to check 
that the loop system is providing the desired level of performance.

Slave

I/O

Output

Metal

Loss

Correction

Compression LEDs

Current LEDs

Overheat

LED

Microphone

Input

Microphone

Gain

Line

Gain

+15V

Loop

Current

Line

Input

Loop

Output

Loop

Monitor

Gain
Boost

Compressor

Phantom
Power
Switch

Overload

LED

Loop
Error

LED

Block Diagram

+15V 

Power

Supply

Power

LED

Earth

Link

230V

or

120V

AC Power

-15V 

0V 

Power

Switch

 15V

150mA

 DC

Output

Socket

0V

+15V

-15V

Use cable supplied.
Must be 3m or less.

Summary of Contents for ILD122

Page 1: ...ord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to any rain or moisture does not operate normally or has been dropped 9 WARNING...

Page 2: ...eld strength meter 10 Adjust METAL LOSS CORRECTION to achieve a flat frequency response All you need is a power source a signal source and a loop See Designing Induction Loops handbook or contact Ampe...

Page 3: ...p cable METAL LOSS CORRECTION Screwdriver adjustable control which compensates for the frequency dependent effects of metal SLAVE I O Post compressor signal for use with ancillaries 15V 150mA DC OUTPU...

Page 4: ...CONNECTOR Signal TIP SOURCE TO ILD122 SLEEVE RING LINE INPUT Connection of 3 pole plug Use Twin screened cable Must be 3m or less Unbalanced Balanced TIP RECORDING DEVICE TO ILD122 SLAVE I O SLEEVE RI...

Page 5: ...including a wire stripper and a small flat bladed screwdriver An ILR3 loop receiver or a magnetic field strength meter is vital to check that the loop system is providing the desired level of perform...

Page 6: ...han 20m in length Total resistance of loop and feed must be between 0 2W and 1 8W at DC The Designing Induction Loops handbook contains more details on loop and feed cables The correct design and posi...

Page 7: ...Metal losses tend to increase with frequency and may require the adjustment of the METAL LOSS CORRECTION As a result of this analysis adjust the LOOP CURRENT and set the METAL LOSS CORRECTION on the...

Page 8: ...Mic Line is turned up Check that there is sufficient signal level for the required input CURRENT LEDs not illuminating Check that the COMPRESSION LEDs are illuminating Check that the LOOP CURRENT cont...

Page 9: ...in instability which may sound like high frequency noise buzz or whistling The results of this type of fault are unpredictable and may appear as any combination of the front panel indication errors T...

Page 10: ...receiver such as an ILR3 If the interference is still present with the loop system switched off then you need to locate and eliminate the source of interference before switching the loop system back o...

Page 11: ...Vpk at 7 0Apk output Input Impedance 200 600W Sensitivity 70dBu 245uV for full RMS 15V 150mA DC Output output 3 pin power Mini DIN socket Overload 5dBu 436mV RMS Regulated DC output for powering Ampet...

Page 12: ...en it is installed Manufacturer Ampetronic Ltd Northern Road Newark Nottinghamshire NG24 2ET United Kingdom Declares that the product Description Induction Loop Driver Type name ILD122 Conforms to the...

Reviews: