background image

a

mpe

res

M

X

2222

PO

W

ER

O

FF

SE

LE

C

T

TU

N

ER

C

D

C

AS

S

O

FF

M

AS

TE

R

M

U

SI

C

 S

O

U

R

C

E

SI

G

 IN

BA

SS

M

AX

M

IN

EX

IN

PU

T

M

AX

M

AX

M

IN

SO

U

R

C

E

M

IN

SI

G

 IN

C

H

IM

E

M

IX

ER

TR

EB

LE

M

AX

M

IN

TO

N

C

TR

L

C

H

5

C

H

6

C

H

4

SI

G

 IN

SI

G

 IN

SI

G

 IN

M

AX

M

IN

M

AX

M

IN

M

IN

C

H

3

C

H

1

C

H

2

SI

G

 IN

SI

G

 IN

M

AX

M

IN

M

AX

M

IN

M

AX

M

IN

M

AX

AU

X

SI

G

 IN

A sample of system with TD6240 zone decoder and few zone selectors

PD2800 PAGING 

MIC

TD6240 DATA 

DECODER

MX2222 MIXER

Power Amplifiers

ZS5121 ZONE SELECTORS

Zone 1 to 12

Zone 13 to 24

Zone 25 to 36

PIN 8-CO M

PIN 7-24V

PIN 6-Z6

PIN 5-Z5

PIN 4-Z4

PIN 3-Z3

PIN 2-Z2

PIN 1-Z1

1

RJ45 Pin configurations.

Note that All Call and PR from remote mic shall not be required.

PIN 8-CO M

PIN 7-24V

PIN 6-Z6

PIN 5-Z5

PIN 4-Z4

PIN 3-Z3

PIN 2-Z2

PIN 1-Z1

PIN 8-CO M

PIN 7-24V

PIN 6-Z12

PIN 5-Z11

PIN 4-Z10

PIN 3-Z9

PIN 2-Z8

PIN 1-Z7

PIN 8-CO M

PIN 7-24V

PIN 6-Z6

PIN 5-Z5

PIN 4-Z4

PIN 3-Z3

PIN 2-Z2

PIN 1-Z1

PIN 8-CO M

PIN 7-24V

PIN 6-Z12

PIN 5-Z11

PIN 4-Z10

PIN 3-Z9

PIN 2-Z8

PIN 1-Z7

PIN 8-CO M

PIN 7-24V

PIN 6-Z6

PIN 5-Z5

PIN 4-Z4

PIN 3-Z3

PIN 2-Z2

PIN 1-Z1

PIN 8-CO M

PIN 7-24V

PIN 6-Z12

PIN 5-Z11

PIN 4-Z10

PIN 3-Z9

PIN 2-Z8

PIN 1-Z7

+

DC 24V

CON

RLY

TRIG

RLY

PR

ZS

to TD6240 Unit 1 

Trigger Port 1

to TD6240 Unit 1 

Trigger Port 2

to TD6240 Unit 1 

Trigger Port 3

to TD6240 Unit 1 

Trigger Port 4

to TD6240 Unit 2

Trigger Port 1

to TD6240 Unit 2

Trigger Port 2

For Zone 1 to 12

For Zone 13 to 24

for Zone 25 to 36

ALL CALL to all units can be triggered from paging mic.

Pressing ALL CALL button from zone selector front panel shall only trigger 

all zones of the particular unit only. And the connection ZS PR must link.

Use EP1200A to make ALL CALL to all ZS installed - refer to page 6

+

DC 24V

CON

RLY

TRIG

RLY

PR

ZS

+

DC 24V

CON

RLY

TRIG

RLY

PR

ZS

Switching signal

audio

Multiple Unit Installation (Cascading)

ZS5601 / ZS5121 | ZONE SELECTOR

PAGE 5

Link the PR ports

Summary of Contents for ZS5601

Page 1: ...ment in PA installations With its gradual improvements over the years in terms of features construction and parts it is no doubt being the most wanted tool for PA setup Although it is not difficult to...

Page 2: ...ing this switch regardless of any inactive zone Switching for zone 1 to 6 switching for zone 7 12 for ZS5121 only 2 3 4 ZS 5121 5 6 7 8 9 10 5 DC SUPPLY INPUT PORT 24V DC supply is required to operate...

Page 3: ...IFIER ZONE OUTPUT CONNECTORS ZONE 1 TO 6 Output from amplifiers are connected to these terminals and speaker zoning is configured to the respective unit of ampli fier The user has the flexibility to c...

Page 4: ...ier unit 1 is to serve zone 1 and 2 Power amplifier unit 2 is to serve zone 3 1 2 3 4 The diagram above shows installation of a 3 zone system with remote triggering employing external switches this is...

Page 5: ...PIN 5 Z11 PIN 4 Z10 PIN 3 Z9 PIN 2 Z8 PIN 1 Z7 PIN 8 COM PIN 7 24V PIN 6 Z6 PIN 5 Z5 PIN 4 Z4 PIN 3 Z3 PIN 2 Z2 PIN 1 Z1 PIN 8 COM PIN 7 24V PIN 6 Z12 PIN 5 Z11 PIN 4 Z10 PIN 3 Z9 PIN 2 Z8 PIN 1 Z7 P...

Page 6: ...ZS PIN 8 COM PIN 7 24V PIN 6 Z6 PIN 5 Z5 PIN 4 Z4 PIN 3 Z3 PIN 2 Z2 PIN 1 Z1 DC 24V CON RLY TRIG RLY PR ZS Connecting Emergency Overriding Port PAGE 6 ZS5601 ZS5121 ZONE SELECTOR to trigger volume con...

Page 7: ...ated 482 x 44 x 180 mm 1 7 kg 6 8W 0 28A w All Call Cascade limitation 6 12 6 Individual zone switch Priority 2 1 kg RJ45 CONNECTOR TO REMOTE PAGING MIC NOTE ON UPGRADE VERSION Connection to remote pa...

Page 8: ...the purchaser or the dealer for the period out of use of the unit moreover the warranty does not cover any damages which may be caused to people and things when using the product This warranty certif...

Reviews: